System information
Fixes/Changes from 2.06.07 to 2.06.08:
SIMPL Windows: Fixed crash that can sometimes occur when trying to access Serial Upload Settings dialog on
devices.
Fixes/Changes from 2.06.06 to 2.06.07:
SIMPL Windows: Made it such that when trying to drag a Serial/IR/RF device from one Serial/IR/RF card to another,
the user can now drop the device onto a Serial/IR/RFl card - instead of having to expand the card to select a
specific Port/ID.
Fixes/Changes from 2.06.05 to 2.06.06:
SIMPL Windows: Due to the the fact that the UPX is a slotted device, and the touchpanel associated with that
device is a sub-slot, SIMPL Windows is not able to copy the programming on the UPX touchpanel to the touchpanel
it is being replaced with. A note to the "Replace Device x with Device y" message box is now issued to let the user
know that programming may be lost.
SIMPL Windows: Changed references of AppBuilder to SystemBuilder.
SIMPL Windows: Fixed data initialization error that was causing problems with "Analog Out is Signed" property
SIMPL Windows: Fixed problem with Create Archive not getting embedded SIMPL+ modules when the SIMPL
Modules were encrypted.
SIMPL Windows: Fixed problem with the function that creates the '<systemname>_files.XML' file. This function was
being called after a compile was done via System Builder and, because of errors that occurred in the Creation of
the XML file, it appeared as though the compile failed.
Library Update Changes: (NOTE: Below Library Update changes are from last standalone library update (v318) to
current (v321))
Expose QM-MD5x1, MT-1000, QM-FTB devices
Correct Power factors for QM-FTCC, QM-FTDC, QM-FTMC, MT-500C, ML-500, WPR-48 (IR/RF418/RF433)
Allow serial devices in the Crestron Database to be dropped on a DAP8 COM port
Correct default ID for CNAMPX-16x60 to 3D
Fix Cues for C2N-VEQ4, C2VEQ-4 for system builder compatibility.
Create "Shades/Drapes" symbol category.
Correct Serial cues for QM-MD7x2
Correct No Mic To Mix cue for QM-MD7x2 mixers
Fixes/Changes from 2.06.04 to 2.06.05:
SIMPL Windows: Added logic in to compensate for Parameter Cues that might have "==" in their names. The data
after the "==" implies the default value. This logic was added in case some client application (D3Pro, System
Builder, etc.) is making a function call to find a matching cue and does not pass in the default value data.
Fixes/Changes from 2.06.03 to 2.06.04:
SIMPL Windows: Fixed logic for importing logic from Crestron Modules and connecting that logic to certain devices.
An error occurred, via System Builder, when doing so with a CLW-DIMS. The analog input/output was no longer
getting connected.
SIMPL Windows: Remove "Minimum CUZ" from the leading comment that appears on the console (or doing "Info -\>
Rems" on a 2 Series front panel display) along with other program information. 2 Series only change.
Fixes/Changes from 2.06.02 to 2.06.03:
SIMPL Windows: Added support of devices that will not allow programming via the SIMPL Windows visual interface.
SIMPL+: Fixed toolbar icons that broke in the previous build.