System information

Icons: Icons for modules that have any kind of Default Logic (for User Interface devices, Cresnet/Ethernet devices
or Front Panel objects) will have distinguising icons that will appear to be reddish versions of the regular icons.
Context Menus: Right clicking on modules with Default Logic will allow the programmer to view which devices and/or
Front Panels the module supports.
Drag and Drop in Program Tree: dragging (from Program Tree) and dropping the module to a device symbol, while
holding the Right Mouse Key down, will present the programmer with actions that can be implemented for importing
the appropriate Default Logic. E.g. If the device is a touchpanel and the module contains GUI Connection Logic, the
context menu will have an option to "Import User Interface Logic".
SIMPL Windows Error Resolutions:
Fixed problem with Detail View freezing up sometimes after scrolling.
Fixed problem with Error Log being lost forever if it was placed on a 2nd monitor and then the user takes that
monitor out of the configuration.
Fixed problem with allowing 4 digits to be entered in IP Address octects.
Removed support of PDF Help for Devices in Device Library Tree. This is because the Crestron Product Catalog
CD is no longer distributed. Hitting F1 on items in the Device Tree of Config Manager will bring up the associated
SIMPL Windows help.
SIMPL+ Enhancements:
Removed ability to launch Viewport from the menu.
Allow Custom Category Name for modules.
Added Expansion Compiler Directives values.
Fixes/Changes from 2.07.35 to 2.07.36:
SIMPL Windows: Fix issue where the following button panels would not compile correctly for a 2 Series Processor if any of
the "fbck" or "press" signals were left out. This would manifest itself at runtime with button presses potentially triggering
the wrong signal, feedback to the panel potentially showing up on the wrong LED, or error messages on the console/in
the error log similar to "Error: Invalid join number -1 in BuildCresnetReallyShortAnalog_XXh. (0011:0000:0011)" This
issue was present in SIMPL Windows 2.07.24 through SIMPL Windows 2.07.35.
CNWPGB2-32
CNPI-48
CNWMBG-10A
CNWP-64
CNWMBG2-34A
CNWPGB2-64
Fixes/Changes from 2.07.34 to 2.07.35:
SIMPL Windows:
Fixed error in Resych Program that was causing some signals to get connected to the wrong outputs.
Fixed an issue with System Builder not being able to open a program if it needed to be resynched.
Addressed issue of adding some devices with default logic causing the program data to become corrupt.
Updated Library to 391.
Fixes/Changes from 2.07.32 to 2.07.34:
Library Update 390:
Change APAD power factor to 3W
Change CEN-IPOD to CEN-IDOC
Correct CLF-DIMRF Firmware Name
Add "Activity Detection" Device Extender to:
TPS-12 (Ethernet)
TPS-15 (Ethernet)
TPS-17 (Ethernet)
TPMC-10