System information
reopened. Now, if any subfolder has a protected module below it, the subfolder can no longer be deleted.
Any non-protected symbols below that subfolder, however, can be specifically deleted.
Will now hide any device extenders that have only protected programming if the "Don't show system control
programming" flag is set.
Library Update Version 531 (Changes from 523):
Expose MPS-300 model
Expose CEN-UPS1250 model
Update C2N-CB-TS Model Parameters
Add SNMP model to device library
Correct SIMPL+ Help file for 2.10.XX SIMPL Windows
Fixes/Changes to 2.10.17 to 2.10.18:
SIMPL Windows Bug Fixes:
Fixed error introduced in 2.10.17 that caused System Builder generation times to be tripled.
SIMPL Windows Enhancements:
SIMPL Windows: Added logic to the Device Library Tree's right click menu to no longer show the "Add Multiple
Copies" if the selected device is a control system or, if the selected device is an SNMP or Poll Accelerator and the
maximum allowed number of SNMP's and/or Poll Accelerator's are already in the program.
Library Update Version 523 (Changes from 520):
Use INCLUDE2.DAT file for better compatability with older versions of SIMPL Windows that use INCLUDE.DAT. This
was done becuase of structural changes to the file. This change should be transparent to users.
Fixes/Changes to 2.10.16 to 2.10.17:
SIMPL Windows Bug Fixes:
Fixed error when compiling from System Builder.
Fixes/Changes to 2.10.15 to 2.10.16:
SIMPL Windows Bug Fixes:
Fixed problem when trying to copy multiple signals to an area of a symbol that contained an Input/Output group that
was collapsed. In these cases, instead of signals being pasted inside the group, which they should have been, the
entire group was skipped and the first non-group items would get the pasted data.
Fixed problem where clicking on Ctrl+A in a symbol's detail view would not select signals inside an Input/Output
group. Now, when the programmer wants to select all signals, all Input/Output groups will be expanded and then all
signals will be selected.
Fixed problem with SIMPL Windows hanging when using Ctrl+C and Ctrl+V to try to copy and paste fixed signals on
an OOTBF symbol.
Fixes/Changes to 2.10.12 to 2.10.15:
SIMPL Windows Bug Fixes:
SIMPL Windows: Added logic to mark modules as having incomplete programming if:
The module is saved and there are inputs or outputs on the Argument Definition symbol that do not have
signals.
If there are symbols in the module that are incomplete.
If there are nested Group Labels or if there are incomplete Groups (i.e. a Begin without an End or an End
without a Begin).
If a module is marked as having incomplete programming, the module will not show up in the Symbol Library and
cannot be added to a program via a speedkey. If a module with incomplete programming is already in a program,
and that program is opened, a warning will appear in the error log warning the user that the module will need to be
completed.