System information
Crestron Devices.
F6 will now be the hotkey to use to display the Configuration dialogs of a device in the System Configuration tree,
on the Configuration Manager page. Note: this option used to show ALT+C as the hotkey.
Adding a CEN-NVS100 to a program should automatically set the CEN-NVS100
�
s device symbol's IP-ID parameter
to the Ethernet IP ID to which the device is located.
SIMPL+ Bug Fixes:
Fixed translation issue with INTEGER_PARAMETER, LONG_INTEGER_PARMETER,
SIGNED_INTEGER_PARAMETER, SIGNED_LONG_INTEGER_PARMETER where the result would sometimes get
treated as an unsigned entity.
Fixes/Changes to 2.11.14 to 2.11.18:
SIMPL Windows Bug Fixes:
Fixed error where selecting the DM-MD8x8 on the module header Connection Logic dialog was not generating any
programming logic for the module.
Fixes/Changes to 2.11.12 to 2.11.14:
SIMPL Windows Bug Fixes:
Correct issue with the compiler not flagging jammed signals in the 2 series compiler on the end of compilation
dialog. They still did appear in the log file, though.
SIMPL+ Bug Fixes:
Correct issue with a source file being marked as "dirty" if a key is pressed that didn't physically change the file (i.e.
SHIFT, ALT, CTRL, etc.)
Fixes/Changes to 2.11.11 to 2.11.12:
SIMPL Windows Bug Fixes:
Correct compilation issue (introduced in 2.11.11) in both X and 2 Series compilers where escape sequences in
strings (characters proceeded by "\", i.e. "\x20", "\n", etc.) were not being processed correctly - they would stay as
literal characters instead of being processed.
Fixes/Changes to 2.11.10 to 2.11.11:
SIMPL Windows Bug Fixes:
Fixed problem with not being able to resize the File -> Save/Open dialog.
Fixed issue with focus not being retained when ALT-TAB was used to switch away from and back to SIMPL
Windows
Fixed issue where signals reported with multiple driving sources could not be traced from the compile log window.
Fixed issue with F9 clearing the error log inadvertantly.
Fixed issue with both X Generation and 2 Series compilers: If "\x00" was used in the delimiter field of a String I/O
Symbol, 1 Way IR driver, or a COM port, it would not get properly appended to the parameters. Other delimiters
would properly get appended, however.
Fixes/Changes to 2.11.09 to 2.11.10:
SIMPL Windows Bug Fixes:
Fixed a bug where the compiler would complain that it could not find/open a "DCR" file.
Fixed a data integrity error that would occur if you had a bookmark, deleted a symbol that was contained in that
bookmark, and then saved. Next time the file is opened, you would receive the data integrity error.
Fixes/Changes to 2.11.08 to 2.11.09: