Specifications

QuickMedia Receiver/Processor Crestron QM-RMCRX
NOTE: Signals on digital I/O port may not transfer to digital input port on QM-
RMCRX.
Converting SIMPL+ Modules for 2-Series
1. Open the SIMPL+ module you want to convert.
2. Choose the 2-Series processor as the target by clicking the toolbar
button, as shown in the following illustration.
SIMPL+ Toolbar
NOTE: Note that you can select both X and 2-Series as the targets, so that the
module works for both types of control systems. However, you are limited to
SIMPL+ keywords and functions that are supported on both systems. If you do
not choose a target, then the module may or may not work, depending on the
constructs that are used.
3. Save and compile the module by clicking the Save and Compile
toolbar button; alternatively, click Save and Compile on the Build
menu (or press F12).
Converting User Modules
1. Open the User module you want to convert.
2. Click Project | Edit Program Header.
3. Click 2-Series in the Target Control System Classes list box.
You can select other types of control systems as well, but then you are limited to
symbols that are supported by all of these platforms. The module may still work
on unselected control systems so long as unsupported symbols are not used.
Selecting a control system means that you are requiring the module to work
there.
50 QuickMedia Receiver/Processor: QM-RMCRX Operations Guide - DOC. 6236