System information
Reference Guide Crestron 2-Series Control System
94 • 2-Series Control Systems Reference Guide – DOC. 6256A
2-Series Console Commands (continued)
CARDS
Description: This command displays the cards in the system.
Help Menu(s): Main, System
Syntax: CARDS
Parameters: none
Possible Source: RS-232, CTP, Telnet, User Program
Minimum CUZ: 1.001
Processor Group: All Processors
CD
Description: This command changes the current working file directory. Refer to "File System" in this Reference Guide
for details. The parameter to this command can be relative or absolute. Entering the command without a
parameter displays the current setting.
Help Menu(s): File
Syntax: CD [directory]
Parameters: directory – ASCII string representing the desired directory
Possible Source: RS-232, CTP, Telnet, User Program
Minimum CUZ: 1.001
Processor Group: All Processors
CFAUTORUN
Description: This command enables/disables the autorun feature of compact flash. If enabled, the program residing
on the compact flash is immediately started when the compact flash card is inserted into the system.
Also, any web pages that reside on the compact flash are immediately active. If autorun is enabled when
the compact flash is extracted and the system is currently running a programfrom the compact flash, the
processor stops the currently running program and restarts with the program stored on internal flash.
Entering the command without a parameter displays the current setting.
Help Menu(s): File
Syntax: CFAUTOrun [ON | OFF]
Parameters: ON - turns on compact flash autorun
OFF - turns off compact flash autorun (default)
Possible Source: RS-232, CTP, Telnet, User Program
Minimum CUZ: 2.004
Processor Group: Compact Flash Processors
CFLOGERR
Description: This command enables/disables logging errors to compact flash. The errors are written to a file in the
root of compact flash named ErrorLog.Txt. This command can be used to protect the error log from a
processor report (which would clear the normal error log). Entering the command without a parameter
displays the current setting.
Help Menu(s): File
Syntax: CFLOGerr [ON | OFF]
Parameters: ON - turns on compact flash error logging
OFF - turns off compact flash error logging (default)
Possible Source: RS-232, CTP, Telnet, User Program
Minimum CUZ: 2.004
Processor Group: Compact Flash Processors