Forcing Signal Transitions
Test Manager provides several commands for changing the states and values of
signals in the Status Window without need to physically press buttons on a device.
These commands are available on the Test Manager toolbar or the Status Window
menu.
Digital Signals
To change the state of a digital signal, select the signal in the Status Window and
click the desired action on the toolbar. Here the commands are only enabled for
"jammable" digital signals, such as button presses or the outputs of buffers.
• Click
(or Assert Signals) to drive the signal high.
• Click
(or De-Assert Signals) to drive the signal low.
• Click
(or Positive Pulse Signals) to pulse the signal high
• Click
(or Negative Pulse Signals) to pulse the signal low.
Analog Signals
To change the value of an analog signal, select the signal in the Status Window and
click the Analog
button, or select Modify Analog Signal from the Status
Window menu. Enter the new value and set the numeric format to Decimal, Percent
or Hex as shown in the following diagram.
“Modify Analog Signal” Window
Serial Signals
To change the value of a serial signal, select the signal in the Status Window and
click the Serial
button, or select Modify Serial Signal from the Status Window
menu and enter the new value. As shown in the following diagram, Test Manager
supports escape codes for non-printable characters such as carriage return/line feed.