Control System IP Table
IP table information can be entered in one of two ways. The first method creates
what is referred to as a “default” IP table based on information given in the SIMPL
Windows program. The second method uses Crestron Toolbox to manage the IP
table.
NOTE: IP tables used in Ethernet-based Master-Slave applications have their own
IP table requirements. Refer to “Ethernet Master-Slave Modes” on page 36 for
details.
Creating the Default IP Table from SIMPL Windows
While adding Ethernet devices (Ethernet slave processors, Ethernet-enabled
touchpanels, Ethernet devices, or Ethernet modules), the IP information for each
device must be entered in Configuration Manager to determine the information
contained in the default IP table.
1. Double-click the Ethernet device in the SIMPL Windows Configuration
Manager screen to open the “Device Settings” window.
2. Select the IP Net Address tab.
Device Settings Window
3. Click the IP ID button and select the hexadecimal IP ID from the list (The
Remap IP ID at program upload option is reserved for future use.)