System information
Crestron 2-Series Control Systems Reference Guide
Reference Guide – DOC. 6256A 2-Series Control Systems • 41
software settings for the IP ID match. For IP ID hardware settings details, refer to
“Ethernet Slave Mode” on page 36.
Expand the device to view the available slots in the MP2/MP2E remote processing
symbol. The following diagram shows the available slots of an MP2E operating in
slave mode.
Device Detail
NOTE: Each Ethernet device has a unique IP ID in the program. If the IP ID is in
use by another device, SIMPL Windows will look for an available IP ID starting at
03.
NOTE: The C2Net-Device and C2ENET-Device slots are never available on a
control system operating in slave mode. All other slots may be configured as
described in the slave system’s respective manual. Slave devices do not control other
network devices.
Programming a Control System as a Master Control System
There are no special procedures for programming a control system that is operating
in the master mode. Refer to the control system’s Operations Guide for programming
instructions.
Programming a Control System as a Slave Device
The slots on a slave device are programmed as described in the slave device’s
Operations Guide.
Uploading
After completing the program in SIMPL Windows, upload the program to the master
control system. A slave device’s configuration information will be automatically
transferred by the master control system. Additionally, the default IP table can be
uploaded after the SIMPL Windows program has been uploaded to the control
system.