System information
Crestron 2-Series Control Systems Reference Guide
Reference Guide – DOC. 6256A 2-Series Control Systems • 15
• Number of data bits = 8.
• Number of stop bits = 1.
• Hardware handshaking (RTS/CTS) enabled.
• Software handshaking (XON/XOFF) not enabled.
4. Power down the control system.
5. In Crestron Toolbox, open a text console to the new address book entry.
6. While powering up the control system, press and hold ALT + K on the
keyboard (for the QM-RMC and QM-RMCRX(-BA), press Enter after
pressing ALT + K) until the following text (or similar) appears in the
Crestron Toolbox text console:
System Monitor [v1.001 (0001)]
12-19-01 16:25:23 32 MB RAM, 4MB FLASH
CS>
7. Increase the baud rate to 115200 by opening the “System Info” window,
selecting Functions | Serial Communications, and selecting 115200 as the
new baud rate. Click OK or Apply to set the new baud rate.
NOTE: Crestron Toolbox will automatically change the baud rate it uses to
communicate with the control system for the current session to ensure that
communications are maintained.
8. From the text console window, adjust the baud rate of the PC to control
system connection by clicking
and selecting 115200 as the new baud
rate.
9. At the control system prompt, type erase and press Enter. The following
text appears in the console window.
CS>erase
->25%->50%->75%->100%
Done
CS>
10. Send the new firmware file as described in “Firmware Upgrade” on page
67.
NOTE: The following processor firmware versions require the selection of
a CE*.CSU file that can be extracted from the .CUZ file using WinZip or
other ZIP file extraction tool:
• CNX-DVP4/C2N-DVP4DI: 2.006, 3.017
• MP2/MP2E: 3.016
• QM-RMC: 3.052
After extracting the CSU file, select it and click Open.
Once “Completed Successfully” appears in the text console window, close the text
console window.