System information
Crestron 2-Series Control Systems Reference Guide
Reference Guide – DOC. 6256A 2-Series Control Systems • 167
b) As shown in the following diagram, select the hexadecimal IP ID of the
control system from the IP ID list. The IP ID of the control system
must match the IP ID that is specified for the control system in the
SIMPL Windows program.
“IP Table Entry” Window
c) In the IP Address/Hostname field, enter the static IP address of the
control system, or if the device is DHCP-enabled, its fully-qualified
domain name.
d) After entering all of the information, click OK to add the control
system to the IP table.
4. Repeat this procedure for all the control systems in the program.
5. Once all of the control systems have been listed, click Send to Device* to
upload the IP table to the touchpanel.
Whenever an IP table is sent to the touchpanel, it will overwrite the previously
loaded IP table and reboot the touchpanel.
For this example, the complete IP table in the control room touchpanel will contain:
IP Table: CIP_ID DeviceID IP Address/SiteName
3 20 192.168.001.010
3 21 192.168.001.011
3 22 192.168.001.012
6 192.168.001.015
Where Device ID 20 is classroom 1, Device ID 21 is classroom 2, and device ID 22
is classroom 3. Note that CIP ID 6 is the control system located in the control room.
This control system does not require a Device ID.
The Classroom Program
Each classroom has the same program that uses join numbers 1 through 15 to operate
the camera tilt-head. Refer to the following diagram for a view of joins 1 through 15.