System information
Crestron 2-Series Control Systems Reference Guide
Reference Guide – DOC. 6256A 2-Series Control Systems • 153
Super Debugger Command Listing (continued)
-S[0|1]
Description: Shows current debug settings. This will list devices that have their debug flag turned on, and list the state of
all debug flags. Form 0 shows a form that is more machine parseable, while form 1 shows a format that is
more verbose.
-OP[#]
Description: Sets a Quick Profile (up to three) using the current parameters. Quick Profiles are built-in sequences of
flags to set up commonly used options for the super debugger. Using “-QP?” will show current parameters
of the three stored profiles:
-QP1: -TXRON, -TXIOFF, -TXF0, -RXRON, -RXIOFF, -RXF0, -PROFF, -PIOFF, -SBON, -SUON, -
OOFF, -CONON, -CFOFF, -STON, -SDON
-QP2: -TXROFF, -TXION, -TXF0, -RXROFF, -RXION, -RXF0, -PROFF, -PION, -SBOFF, -SUOFF, -
OON, -CONON, -CFOFF, -STON, -SDON
-QP3: -TXROFF, -TXION, -TXF1, -RXROFF, -RXION, -RXF1, -PROFF, -SBOFF, -SUOFF, -OON, -
CONON, -CFOFF, -STON, -SDON
-CON[on|off]
Description: Writes the debug output to the console. By default, this option is on, Turn this feature off when logging data
to compact flash without being actively connected to the console.
-CF[on|off]
Description: When set to ON, the super-debugger output is logged to the compact flash file \CF0\sdebug.txt.
-ST[on|off]
Description: When set to ON, a time stamp is printed before the packet.
-SD[on|off]
Description: When set to ON, data is shown when the time is printed. This command requires the -ST option to be ON.