System information
Reference Guide Crestron 2-Series Control System
148 • 2-Series Control Systems Reference Guide – DOC. 6256A
Error Level Messages, U (continued)
MESSAGE DEFINITION
Unable to create
waitname
WaitEventTimer.
Internal system error. Contact Crestron.
Unable to destination
open file: filename.
The system is unable to open file filename for writing.
Unable to find
WaitEvent waitname.
This error is generated when the wait event has already expired or
the wrong name is used.
Unable to pause
WaitEvent name.
This error is generated when the wait event has already expired or
the wrong name is used.
Unable to remove
WaitEvent name from
list.
This error is generated when the wait event has already expired or
the wrong name is used.
Unable to resume
WaitEvent name.
This error is generated when the wait event has already expired or
the wrong name is used.
Unable to retime
WaitEvent name.
This error is generated when the wait event has already expired or
the wrong name is used.
Unable to send
Packet in CIP
Transmission
Symbol/Device#.
(0049:####:0049)
This is a general failure attempting to send the packet.
Unable to source
open file: filename.
The system is unable to open file filename for reading.
Unable to start
WaitEvent waitname.
Internal system error. Contact Crestron.
Unknown subtype
#### for packet type
18 - Internal Control
Packet.
(0038:####:0038)
Internal system error. Contact Crestron.
Unsupported console
command (string)
detected in
Symbol/Device#.
(0033:####:0033)
The Message to Computer Port (TMSG) and Console symbols
attempt to interpret some old-style ESC commands from the X
generation and older control systems. The only ESC commands
that are supported are the ESC X C and ESC X M commands, for
compatibility with Crestron Macros that are written to use these
commands.
UpdateFTE: attempt
to overwrite SETUP
file.
An attempt was made to overwrite a read-only file in the \SETUP
directory.
UpdateFTE:
exceeded maximum
files allowed.
The maximum number of files for the internal flash system has been
exceeded.
UpdateFTE: unable to
obtain filelist
semaphore.
Internal system error. Contact Crestron.
W
MESSAGE DEFINITION
Wait Event name too
long.
The name given to the Simpl+ event is greater than 256 characters.
Use a shorter name.
(continued on next page)