Error Level Messages, R (continued)
MESSAGE DEFINITION
ReadSplus: Incorrect
number of Loadable
program segments:
nn.
The Simpl+ file was corrupted. The program should be recompiled
and resent.
ReadSplus: Simpl+
Module too large: nn.
The amount of space for all Simpl+ modules has exceeded the
space allotted in the control system.
RegisterTaskAsFlash
User: Error creating
new node.
Internal system error. Contact Crestron.
RejectSocketConnecti
on: unable to close
new socket.
Internal system error. Contact Crestron.
ReleaseInputStream:
unable to release
semaphore.
Internal system error. Contact Crestron.
ReleaseSemaphore:
Error Releasing
Semaphore.
Internal system error. Contact Crestron.
RemoveEntryFrom
MasterList: Node not
found.
An attempt was made to remove an entry from the IP table that did
not exist.
RemoveGatewayLink:
node not found.
Internal system error. Contact Crestron.
RetransmitTimer:
error retrieving
NODE_ADDED flag:
nn.
Internal system error. Contact Crestron.
RomAppendFile:
failed to (un)lock
flash.
Internal system error. Contact Crestron.
RomAppendFile:
failed to write new file.
An internal file write operation to the internal flash failed.
RomAppendFile: not
enough free flash
space.
The internal flash file system is full. A “COMPACT” operation may
free up room to allow the file to be stored.
RxConsoleData: Error
sending to pipe.
Internal system error. Contact Crestron.
S
MESSAGE DEFINITION
SaveList: Error
opening file.
Internal system error. Contact Crestron.
SaveList: Not enough
space to store IP
table.
The file system was full and could not store the new IP settings.
Run “COMPACT” command from console.
SendCaptured
OutputMsg: Error
transmitting message
Internal system error. Contact Crestron.
SendCaptured
OutputMsg: invalid
source.
Internal system error. Contact Crestron.
(continued on next page)