System information
Crestron 2-Series Control Systems Reference Guide
Reference Guide – DOC. 6256A 2-Series Control Systems • 139
Error Level Messages, I (continued)
MESSAGE DEFINITION
IR Queue Overflow on
Symbol/Device#.
(005B:####:005B)
IR devices (cards or network devices) have only a specific number
of commands that can be queued up. Since IR commands are
relatively slow to generate compared to how fast the user may want
to generate them, a queuing mechanism is needed. The queue is
currently 32 commands deep (32 “start” IR commands and 32 “stop”
IR commands; a typical button press and release to generate IR is
two commands, a start and stop). If greater than this number of
commands is queued, the current queue is dumped and the new
command is considered the first command.
J
MESSAGE DEFINITION
Jog Time parameters
for Symbol/Device#
must be 2.55s or less,
clamping to 2.55s.
(0066:####:0066)
This error refers specifically to the CLX-1MC4 Motor Control
module. Even though a broad range of times can be entered for the
Max Time/Jog Time/Lockout Time parameters in SIMPL Windows,
there is a run-time restriction that is enforced when the system
initializes. If the time for a particular parameter is too large, it will
lock it to the specified maximum value.
L
MESSAGE DEFINITION
Lockout Time
parameters for
Symbol/Device# must
be 2.55s or less,
clamping to 2.55s.
(0067:####:0067)
This error refers specifically to the CLX-1MC4 Motor Control
module. Even though a broad range of times can be entered for the
Max Time/Jog Time/Lockout Time parameters in SIMPL Windows,
there is a run-time restriction that is enforced when the system
initializes. If the time for a particular parameter is too large, it will
lock it to the specified maximum value.
Lower and upper
bounds must be
greater than 0 in
LogAntilog
Symbol/Device#.
(006C:####:006C)
The log/antilog symbol may not have 0 as either the upper or lower
bound, as this will result in a divide by zero error. If this error
message is issued, the log/antilog symbol will NOT perform any
processing in response to transitions on its inputs.
M
MESSAGE DEFINITION
Max Time parameters
for Symbol/Device#
must be 655.35s or
less, clamping to
655.35s.
(0065:####:0065)
This error refers specifically to the CLX-1MC4 Motor Control
module. Even though a broad range of times can be entered for the
Max Time/Jog Time/Lockout Time parameters in SIMPL Windows,
there is a run-time restriction that is enforced when the system
initializes. If the time for a particular parameter is too large, it will
lock it to the specified maximum value.
Memory allocation
error in ReadSplus.
Internal system error. Contact Crestron.
Message from device
Symbol/Device#:
{message}
(0056:####:0056)
If a device has a specific error to give back (such as a device on
Cresnet or Ethernet), it is put into this message. Examples are
framing errors from ST-COMs or any error message generated in a
slave 2-Series control system. In a slave, error message are also
locally stored in the slave’s error log in addition to being put in the
master’s error log.
(continued on next page)