System information

Reference Guide Crestron 2-Series Control System
136 2-Series Control Systems Reference Guide – DOC. 6256A
Error Level Messages, E (continued)
MESSAGE DEFINITION
Error sending signal
transition to SIMPL+
module modulename
in modulenumber.
(0028:####:0028)
Internal system error. Contact Crestron.
Error setting default
directory for console.
Internal system error. Contact Crestron.
Error skipping past
header.
(0059:####:0059)
Internal system error. Contact Crestron.
EtherDisconnect:
unable to close
socket.
Internal system error. Contact Crestron.
EtherTask: Error
setting default router
The parameter used for the default router is incorrect. The default
router should be on the same subnet as the system (LAN A for
C2ENET-2 cards).
EtherTask: Error
setting DEVICE_INIT
flag
Internal system error. Contact Crestron.
EtherTask: Listen
socket never created.
Internal system error. Contact Crestron.
EtherTask:
NU_Init_Devices
failed.
Internal system error. Contact Crestron.
EtherTask:
NU_Init_Net failed.
Internal system error. Contact Crestron.
EtherTask:
WARNING! Single
Ethernet Device: NAT
is non functional.
The system detected that NAT was enabled but could not be started
because there is only an C2ENET-1 card in the system.
EtherTask:error at call
to NAT_Portmap at
device 0.
An error occurred initializing the port mapping for the NAT. Check
the port map parameters.
F
MESSAGE DEFINITION
File Writing not
currently supported to
internal flash.
The user attempted to open a file for write access on the internal
flash. This is not currently supported. Only compact flash can be
accessed to write files. However, internal flash can be used to read
files.
FindFile: unable to
obtain/release
directory semaphore.
Internal system error. Contact Crestron.
FindFirst: Unable to
create a File info
block.
Internal system error. Contact Crestron.