Warning-Level Messages (continued)
MESSAGE DEFINITION
Lost Ethernet link on
LAN A/B
The system detected that the Ethernet link on LAN A or B was
broken.
Module xxxx : xxxx at
line nnn: No
digital/analog/serial
signal defined at
ArrayName[nn] on
symbol wrapper.
The Simpl+ module has access the array with a valid index but the
symbol wrapper in Simpl does not have a signal defined at that
output. The array has not been expanded that far. The
IsSignalDefined() function call can be used to see if the index has a
valid signal.
Module xxxx : xxxx at
line nnn: No
digital/analog/serial
signal defined at nn
on symbol wrapper
The Simpl+ module has access the array with a valid index but the
symbol wrapper in Simpl does not have a signal defined at that
output. The array has not been expanded that far. The
IsSignalDefined() function call can be used to see if the index has a
valid signal.
Pesa Switch
Command
Symbol/Device# input
1 must be 999 or less
(current value is
####).
(003C:####:003C)
The analog values for the Pesa Switch command are 1-999. The
protocol used only allows for three digits.
String too big in Serial
Demultiplexor
Symbol/Device# -
maximum
intermediate string
size is 255 bytes.
(0037:####:0037)
Format 1 of the Serial Demultiplexor uses embedded characters to
signify the start and end of a string. The largest supported string
supported between the start and stop is 255 bytes.
Symbol
symbol/device# (Type
#### [####]) is
unknown.
(000F:####:000F)
The symbol specified is not recognized in this operating system.
Usually this happens if a program was created in version of SIMPL
Windows utilizing a symbol that was not in existence for the CUZ
that is currently in the system. The symbol number is given in
decimal and in hex; Crestron can track the meaning of the actual
number.
Timeout engaging
slave mode for
Symbol/Device#.
(0061:####:0061)
Command indicates an error trying to configure a slave 2-Series
control system. This usually means there is a network problem
talking to the slave system or such severe latency that it is
exceeding the timeout (currently 20 seconds, subject to change).
Timeout waiting for
response from slave
Symbol/Device#.
(0062:####:0062)
Command indicates an error trying to configure a slave 2-Series
control system. This usually means there is a network problem
talking to the slave system or such severe latency that it is
exceeding the timeout (currently 20 seconds, subject to change).
Unexpected packet
encountered from:
Symbol/Device#
(printout of packet).
(0009:####:0009)
Devices are coded to expect only certain types of packets. If a
device receives a packet it does not understand, this message will
be printed along with a fragment of the packet. This can happen if
the device hooked up physically differs from the one in the program
or there is more than one device at the same ID.
Unexpected
Parameter type ##
encountered while
instantiating S-5.
(000E:####:000E)
Internal system error. Contact Crestron.
Unknown control
packet type ##
received.
(0010:####:0010)
Internal system error. Contact Crestron.