2-Series Console Commands (continued)
REPORTCRESNET
Description: This command shows all devices on the main Cresnet leg.
Help Menu(s): System
Syntax: REPORTCRESNET
Parameters: none
Possible Source: RS-232, CTP, Telnet, User Program
Minimum CUZ: 1.001
Processor Group: Cresnet Processors
RESTORE
Description: This command restores system setup parameters to the factory defaults. It erases any stored program, web
pages, and IP tables.
NOTE: Version 3.015 and earlier of the 2-Series control system update file does not erase the SIMPL
Windows/SIMPL+ program and IP table when activating this command. Contact a member of the Crestron
customer service team to verify the action of this command for later versions.
Help Menu(s): System
Syntax: RESTORE
Parameters: none
Possible Source: RS-232, CTP, Telnet
Minimum CUZ: 1.001
Processor Group: All Processors
RTSCTS
Description: This command enables/disables the hardware handshaking on the RS-232 port. If no parameter is entered,
the current state is displayed.
Help Menu(s): System
Syntax: RTScts [ON | OFF]
Parameters: ON – enables the RTS/CTS handshaking (default)
OFF – disables the RTS/CTS handshaking
Possible Source: RS-232, CTP, Telnet, User Program
Minimum CUZ: 1.001
Processor Group: All Processors
SAVEPARAM
Description: This command forces a system parameter save to EEPROM.
Help Menu(s): Main, System
Syntax: SAVEPARAM
Parameters: none
Possible Source: RS-232, CTP, Telnet, User Program
Minimum CUZ: 1.001
Processor Group: All Processors