System information

Reference Guide Crestron 2-Series Control System
108 2-Series Control Systems Reference Guide – DOC. 6256A
2-Series Console Commands (continued)
NPA
Description: This command configures the Network Poll Accelerator.
Help Menu(s): Main, Device
Syntax: NPA ADD [SLOT num | COM portid | IPID id]
NPA DELETE
NPA TEST num_repeats
NPA BAUD rate
NPA MODE RS232 | RS422
NPA PING
NPA VERBOSE
Parameters: ADD – connect to NPA
SLOT – the next number specifies the slot number for the NPA com connection
COM – the next parameter specifies which internal com port for the NPA connection (A – F)
IPID – the next number specifies the ID in the IP table for the NPA entry
DELETE - deletes the current NPA setting
TEST – tests the poll accelerator for the specified number of repeats
BAUD – the next parameter specifies the baud rate for the NPA connection
MODE – the next parameter specifies the protocol for the com connection
PING - pings the remote NPA
VERBOSE – display extended status
Possible Source: RS-232, CTP, Telnet, User Program
Minimum CUZ: 2.3.085
Processor Group: Cresnet Processors, C2N-NPA8
NVRAMCLEAR
Description: This command clears the program contents of NVRAM. The user is prompted to confirm the clear operation.
If an NVRAM disk has been set up, its contents are preserved. This command provides a quick method to set
the NVRAM contents to a known state.
Help Menu(s): System
Syntax: NVRAMCLEAR
Parameters: none
Possible Source: RS-232, CTP, Telnet
Minimum CUZ: 2.004
Processor Group: All Processors
(continued on next page)