System information

Crestron 2-Series Control Systems Reference Guide
Reference Guide – DOC. 6256A 2-Series Control Systems 107
2-Series Console Commands (continued)
MESSAGE
Description: This command displays a message on the front panel screen. It will be used to display informational
messages during downloads.
Help Menu(s): Device
Syntax: MESSAGE [message_string]
Parameters: message_string – ASCII string to display on panel screen
No parameter clears message from screen and restores display page.
Possible Source: RS-232, CTP, Telnet, User Program
Minimum CUZ: 1.001
Processor Group: Front Panel Processors
MODEMINITSTRING
Description: This command changes the modem initialization string that is sent by the control system at startup. Entering
the command without a parameter displays the current initialization string setting.
Help Menu(s): File
Syntax: MODEMINITSTRING
Parameters: Init string – String to send to modem. 64 characters Max.
No parameter shows current init string.
Possible Source: RS-232, CTP, Telnet, User Program
Minimum CUZ: 3.129
Processor Group: All Processors
NATENABLE
Description: This command enables the Network Address Translator (NAT). Entering the command without a parameter
displays the current setting.
Help Menu(s): Ethernet
Syntax: NATENAble [ON | OFF]
Parameters: ON – enables the NAT
OFF – disables the NAT (default)
Possible Source: RS-232, CTP, Telnet, User Program
Minimum CUZ: 2.004
Processor Group: Ethernet Processors
NATREMOTE
Description: This command enables configuration of the Network Address Translator (NAT) from the WAN (LAN A) port.
Entering the command without a parameter displays the current setting.
Help Menu(s): Ethernet
Syntax: NATREMote [ON | OFF]
Parameters: ON – enables the NAT configuration for the WAN port (default)
OFF – disables the NAT configuration for the WAN port
Possible Source: RS-232, CTP, Telnet, User Program
Minimum CUZ: 2.004
Processor Group: Ethernet Processors