Crestron TPS-6X-DSW Wall Mount Docking Station for TPS-6X Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON Regulatory Compliance As of the date of manufacture, the TPS-6X-DSW has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. Federal Communications Commission (FCC) Compliance Statement This device complies with part 15 of the FCC rules.
Crestron TPS-6X-DSW Wall Mount Docking Station for TPS-6X Contents Wall Mount Docking Station for TPS-6X: TPS-6X-DSW 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Specifications .............................................................................................................
Crestron TPS-6X-DSW Wall Mount Docking Station for TPS-6X Wall Mount Docking Station for TPS-6X: TPS-6X-DSW Introduction The Crestron® TPS-6X-DSW Wall Mount Docking Station facilitates charging of the TPS-6X Isys® Wireless Touchpanel (sold separately) while simultaneously enabling wired touchpanel operation with full motion video capability. It is designed for installation in a flat, vertical wall structure.
Wall Mount Docking Station for TPS-6X Crestron TPS-6X-DSW Vertical Mounting Options The TPS-6X-DSW is designed for easy flush mount installation in a flat, vertical wall structure. A variety of mounting accessories is offered for both pre- and post-construction applications. The TPS-6X-DSW is included with the TPS-6XWALL Isys 5.7” Wall Mount Wireless Touchpanel and is also available separately for use with any TPS-6X model. It is available in high gloss black or white or matte black finishes.
Crestron TPS-6X-DSW Wall Mount Docking Station for TPS-6X Physical Description This section provides information on the connections, controls and indicators available on your TPS-6X-DSW. TPS-6X-DSW Physical View (Shown with TPS-6X Touchpanel Installed) Operations & Installation Guide – DOC.
Wall Mount Docking Station for TPS-6X Crestron TPS-6X-DSW TPS-6X-DSW Overall Dimensions (Front and Side Views) 9.35 in (238 mm) 8.00 in (204 mm) 6.35 in (162 mm) 5.98 in (152 mm) 6.83 in (174 mm) 3.70 in (94 mm) TPS-6X-DSW Overall Dimensions (Front and Side Views with Bezel Attached) 9.70 in (247 mm) 7.11 in 181 mm) 4.17 in (106 mm) 4 • Wall Mount Docking Station for TPS-6X: TPS-6X-DSW Operations & Installation Guide – DOC.
Crestron TPS-6X-DSW Wall Mount Docking Station for TPS-6X TPS-6X-DSW Overall Dimensions (Front and Side Views with Bezel and TPS-6X Touchpanel Attached) 4.50 in (115 mm) TPS-6X-DSW Overall Dimensions (Bottom View with Bezel Attached) 8.89 in (226 mm) TPS-6X-DSW (Front View with Aesthetic Plate Removed to Show Connectors) 1 2 3 4 5 6 7 Operations & Installation Guide – DOC.
Wall Mount Docking Station for TPS-6X Crestron TPS-6X-DSW Connectors, Controls & Indicators # CONNECTORS1, CONTROLS & INDICATORS DESCRIPTION 1 TOUCHPANEL CONNECTOR (1) 10-pin connector for attaching touchpanel 2 LATCH RELEASE 3 OPEN (1) Miniature pushbutton, accessible when touchpanel is not docked, releases the docking mechanism to allow touchpanel to be docked 4 NET (1) 4-pin 3.
Crestron TPS-6X-DSW Wall Mount Docking Station for TPS-6X Setup Network Wiring When wiring the Cresnet® and Ethernet network, consider the following: • Use Crestron Certified Wire. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. CAUTION: Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (www.crestron.com/calculators).
Wall Mount Docking Station for TPS-6X Crestron TPS-6X-DSW Mounting Options The TPS-6X-DSW Docking Station and TPS-6X touchpanel install simply and cleanly into existing or newly constructed walls with an assortment of pre- and postconstruction mounting options. All mounting options are provided separately from the actual touchpanel. Refer to the following table for a complete list of mounting options and respective Installation Guides for these touchpanels.
Crestron TPS-6X-DSW Wall Mount Docking Station for TPS-6X 1. The TPS-6X-DSW is shipped with the docking mechanism locked in its “back” position. In order to make cable connections, the mechanism must first be unlocked so it slides to the “forward” position. To do this, slide the release latch on the right side of the TPS-6X-DSW upward to release the mechanism. The mechanism will slide forward. To locate the release latch, refer to illustration on page 5, showing the front view of the TPS-6X-DSW.
Wall Mount Docking Station for TPS-6X Crestron TPS-6X-DSW TPS-6X-DSW Installation – Secure to Mounting Option NOTE: Either the BB-6X-DSW or PMK-6X-DSW must be installed before installing TPS-6X-DSW into the wall.
Crestron TPS-6X-DSW Wall Mount Docking Station for TPS-6X TPS-6X-DSW Bezel Installation Install bezel with the IR window facing up. Wall Screws (4) #06-32 x 3/16" with Nylon Washers (4509330) Secure bezel to metal chassis box with the supplied screws and washers. 9. Use the four supplied #06-32 x 3/16” screws with washers (4509330), two on the left side and two on the right side, to attached the bezel. 10. The TPS-6X touchpanel can now be docked.
Wall Mount Docking Station for TPS-6X Crestron TPS-6X-DSW Removal If it is necessary to remove the TPS-6X-DSW after it has been installed, complete the following steps in the order provided. The only tool required is a #2 Phillips screwdriver. 1. Undock the touchpanel. Refer to “Undocking the Touchpanel” which starts on page 13 for details. 2. Push the TPS-6X-DSW mechanism backward, into the box, until it locks in place, exposing the screws securing the bezel on the left and right sides.
Crestron TPS-6X-DSW Wall Mount Docking Station for TPS-6X Operation Docking the Touchpanel To mount the TPS-6X, perform the following procedure in the order provided. 1. Press the OPEN button located on the front of the TPS-6X-DSW, to the right of the docking fixture. The mechanism will slide forward. 2. Position the touchpanel onto the TPS-6X-DSW at a slight angle to latch the top portion of the touchpanel to the tab on the top of the docking fixture.
Wall Mount Docking Station for TPS-6X Crestron TPS-6X-DSW Manual Undocking of Touchpanel Using Supplied Emergency Release Tool To release, insert the emergency latch release tool one inch above the lower right corner and lift up. 2. Slide the emergency latch release tool upward to engage the release latch. The TPS-6X-DSW mechanism will slide forward and the tab on the bottom of the docking fixture will slide clear of the recess on the rear of the touchpanel. 3.
Crestron TPS-6X-DSW Wall Mount Docking Station for TPS-6X Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. TPS-6X-DSW Troubleshooting TROUBLE The TPS-6X-DSW does not unlatch the touchpanel. POSSIBLE CAUSE(S) CORRECTIVE ACTION The touchpanel is not properly docked.
Wall Mount Docking Station for TPS-6X Crestron TPS-6X-DSW TPS-6X-DSW Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION The internal battery of the touchpanel does not recharge. The contacts on the TPS-6X-DSW are dirty. Perform “Manual Undocking of Touchpanel” (refer to page 13) and clean the contacts. The internal battery can not retain a charge. Undock the touchpanel and replace the internal battery. The Cresnet connector is not secure.
Crestron TPS-6X-DSW Wall Mount Docking Station for TPS-6X Make sure the cable length value is less than the value calculated on the right side of the equation. For example, a Cresnet run using 18 AWG Crestron Certified Wire and drawing 20 watts should not have a length of run more than 333 feet (101 meters). If Cresnet HP is used for the same run, its length could extend to 1250 feet (381 meters). NOTE: All Crestron certified Cresnet wiring must consist of two twisted pairs.
Wall Mount Docking Station for TPS-6X Crestron TPS-6X-DSW Future Updates As Crestron improves functions, adds new features and extends the capabilities of the TPS-6X-DSW, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision. Check the Crestron website periodically for manual update availability and its relevance.
Crestron TPS-6X-DSW Wall Mount Docking Station for TPS-6X Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations & Installation Guide – DOC. 6708B (2021696) 01.10 Specifications subject to change without notice.