Specifications

Professional Automation Control System Crestron PAC2
16 Professional Automation Control System: PAC2 Operations Guide Doc. 5941A
NOTE: Ensure the unit is properly grounded by connecting the chassis ground lug
to an earth ground (building steel).
NOTE: To prevent overheating, do not operate this product in an area that exceeds
the environmental temperature range listed in the table of specifications.
NOTE: Since the plug on the power supply cord is used to disconnect power from
the unit, the socket-outlet shall be installed near the equipment and shall be easily
accessible.
AC Power Connection
The PAC2 requires ac power for operation. This can be accomplished using the
materials listed in the following table. This involves adding the terminal blocks and
associated parts to the lower left terminal rail in a double-wide CAEN enclosure, or
the lower terminal rail in a single-wide enclosure, and making the necessary wiring
connections. The power cable and hardware required for connection are supplied
with the PAC2.
Supplied Parts for PAC2 AC Connection
QUANTITY/DESCRIPTION PART #
One (1) White, 1-Position Terminal Block JTTB01-4
One (1) Black, 1-Position Terminal Block JTTB01-6
One (1) Terminal Block Partition Plate JTHWXX-3
One (1) Terminal Block End Plate JTHWXX-2
One (1) Terminal Block End Bracket JTHHXW-1
One (1) Power Cord CAXXIPC-65008A-1
Refer to the illustration on the following page and perform the associated procedures.
WARNING: Verify ac power to the CAEN assembly is turned off before
performing any of these assembly or wiring procedures.