Crestron MC2E 2-Series Compact Control System with Ethernet Operations Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2007 Crestron Electronics, Inc.
Crestron MC2E 2-Series Compact Control System Contents 2-Series Compact Control System with Ethernet: MC2E 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Specifications ..............................................................................................................
Crestron MC2E 2-Series Compact Control System 2-Series Compact Control System with Ethernet: MC2E Introduction Features and Functions • • • • • • • • • • • • • • • • • • * 2-Series engine Dual bus architecture 32-bit Freescale Coldfire® processor 36 MB of Internal Memory* Cresnet® port – master/slave selectable 10/100 Ethernet with SSL encryption Crestron e-Control®2 enabled RoomView® enabled Two Com ports (RS-232/422/485) Four IR/serial ports Four Versiport I/O ports Four low-voltage relay ports IR wir
2-Series Compact Control System Crestron MC2E Cresnet® Cresnet is the communications backbone for many Crestron touchpanels, keypads, lighting controls and other devices. The Cresnet bus is a simple, yet flexible 4-wire network that provides rock-solid bidirectional communication for numerous Cresnet devices. Cresnet Slave Mode Selectable Cresnet Slave Mode enables the MC2E to be configured as a Cresnet slave device, effectively transforming it into a Cresnet expansion module.
Crestron MC2E 2-Series Compact Control System Specifications Specifications for the MC2E are listed in the following table.
2-Series Compact Control System Crestron MC2E MC2E Specifications (Continued) SPECIFICATION DETAILS Available Accessories PW-2420RU 50 Watt Regulated Universal Power Supply C2N-HBLOCK Cresnet Network Distribution Block CNSP-XX Custom Serial Interface Cable IRP2 IR Probe CNXRMIRD IR Receiver Physical Description This section provides information on the connections, controls and indicators available on your MC2E.
Crestron MC2E 2-Series Compact Control System MC2E Overall Dimensions 1 2 3 4 5 19.00 in (48.26 cm) 1.70 in (4.32 cm) 17.03 in (43.25 cm) 8.50 in (21.59 cm) 6 7 8 9 10 11 12 13 14 Connectors, Controls & Indicators # CONNECTORS1, CONTROLS & INDICATORS DESCRIPTION 1 PWR LED Indicates 24 Volts DC power supplied from Cresnet control network or external power supply. 2 NET LED Indicates communication with Cresnet System. 3 RESET BUTTONS HW-R - Initiates system hardware reset.
2-Series Compact Control System Crestron MC2E Connectors, Controls & Indicators (Continued) # CONNECTORS1, CONTROLS & INDICATORS DESCRIPTION 6 INFRARED-SERIAL OUTPUT (A – D)3, 4 (4) 2-pin 3.5 mm detachable terminal blocks IR/Serial output ports; IR output up to 1.2 MHz; 1-way serial TTL/RS-232 (0-5 Volts) up to 115.2k baud; Individual signal generator per port, allowing simultaneous firing of all ports. A B C D S G S G S G S G IR SERIAL OUT IR IN 7 (1) 3-pin 3.
Crestron MC2E 2-Series Compact Control System Connectors, Controls & Indicators (Continued) # CONNECTORS1, CONTROLS & INDICATORS DESCRIPTION 11 COMPUTER (1) DB9 female, RS-232 computer console port. Connector is used when programming with a PC. The port is modem compatible (modem and PC cables not included). Supports baud rate of up to 115 kB. Use with standard DB9 straight through cable. Pins 1, 4, 6 and 9 are not connected.
2-Series Compact Control System 9. To support RS-485, tie pin 1 (RXD-) to pin 9 (TXD-) and pin 4 (TXD+) to pin 6 (RXD+) in the cable. (Refer to table at right.) Crestron MC2E COM (DB9) CONNECTOR RS-485 BUS Tie Pins 1 & 9 - Tie Pins 4 & 6 + Pin 5 G 10. The Cresnet Poll Accelerator effectively increases the network speed, fan-out and device addresses by a factor of 8 for each Poll Accelerator added to the system. 11. The MC2E can be powered via the 24 VDC jack or the NET port.
Crestron MC2E 2-Series Compact Control System Setup Network Wiring When wiring the network, consider the following: • Use Crestron Certified Wire. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. CAUTION: Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (http://www.crestron.com/calculators).
2-Series Compact Control System Crestron MC2E Installation Ventilation The MC2E should be used in a well-ventilated area. The venting holes should not be obstructed under any circumstances. To prevent overheating, do not operate this product in an area that exceeds the environmental temperature range listed in the table of specifications. Consider using forced air ventilation and/or incrementing the spacing between units to reduce overheating.
Crestron MC2E 2-Series Compact Control System Ear Attachment for Rack Mounting (this image shows a 1RU device) USE COVER SCREWS 4. Bussing Strip Installation Stacking Operations Guide – DOC. 6142A Repeat procedure (steps 1 through 3) to attach the remaining ear to the opposite side. The 2-Series compact control system is supplied with two brass bussing strips to facilitate commoning (linking) of multiple terminal block connections.
2-Series Compact Control System Crestron MC2E Hardware Hookup Make the necessary connections as called out in the illustration that follows this paragraph. Refer to “Network Wiring” on page 9 before attaching the 4-position terminal block connector. Apply power after all connections have been made. When making connections to the MC2E, consider the following: • Use Crestron power supplies for Crestron equipment. • The included cable cannot be extended.
Crestron MC2E 2-Series Compact Control System Programming Software Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestron’s True Blue Support, log in at http://support.crestron.com. First-time users will need to establish a user account.
2-Series Compact Control System Crestron MC2E Programming with Crestron SystemBuilder Crestron SystemBuilder is the easiest method of programming but does not offer as much flexibility as SIMPL Windows. For additional details, download SystemBuilder from the Crestron website and examine the extensive help file. Programming with D3 Pro Crestron’s D3 Pro lighting software provides all the tools necessary to create a complete Crestron lighting system for residential applications.
Crestron MC2E 2-Series Compact Control System Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. Once communication has been established, files (for example, programs or firmware) can be transferred to the control system (and/or device).
2-Series Compact Control System Crestron MC2E • Confirm Ethernet connections between MC2E and PC. If connecting through a hub or router, use CAT5 straight through cables with 8-pin RJ-45 connectors. Alternatively, use a CAT5 crossover cable to connect the two LAN ports directly without using a hub or router. • Use the Address Book in the Crestron Toolbox to create an entry for the MC2E with the MC2E’s TCP/IP communication parameters. • Display the “System Info” window (click the MC2E entry.
Crestron MC2E 2-Series Compact Control System Operation Crestron 2-Series Control Systems are the brain of a complete integrated audio/visual or automation solution, serving as the central processor and I/O interface. Every audio, video and environmental element of the home, boardroom, classroom or command center becomes integrated and accessible through the control system. No matter how complex or basic, Crestron control systems are entirely customprogrammable to attain the exact functionality required.
2-Series Compact Control System Crestron MC2E Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. MC2E Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Unexpected response from control system. Network devices are not communicating with the control system. Use Crestron Toolbox to poll the network. Verify network connection to the device.
Crestron MC2E 2-Series Compact Control System MC2E Troubleshooting (Continued) TROUBLE System does not function. A/V system device does not respond. POSSIBLE CAUSE(S) CORRECTIVE ACTION Various. Refer to the “System Monitor” procedure following this table. Incorrect power supply. Use a Crestron power supply. IRP2 or serial port not placed properly. Verify placement of IRP2 (hold phosphor card under IRP2 while pressing button) and tighten serial cables. Used wrong IR/serial port.
2-Series Compact Control System Crestron MC2E 5. Power down the MC2E. 6. While powering up the MC2E, press Alt+K then Enter, repeating Alt+K then Enter on the keyboard until the following text (or similar) appears in Toolbox. System Monitor [v1.001 (0001)] 12-19-01 16:25:23 32MB RAM, 4MB FLASH CS> 7. At the Toolbox prompt, type erase and press Enter. The following text appears in Toobox. CS>erase ->25%->50%->75%->100% Done CS> 8.
Crestron MC2E 2-Series Compact Control System Check Network Wiring Use the Right Wire In order to ensure optimum performance over the full range of your installation topology, Crestron Certified Wire and only Crestron Certified Wire may be used. Failure to do so may incur additional charges if support is required to identify performance deficiencies because of using improper wire. Calculate Power CAUTION: Use only Crestron power supplies for Crestron equipment.
2-Series Compact Control System Crestron MC2E Reference Documents The latest version of all documents mentioned within the guide can be obtained from the Crestron website (http://www.crestron.com/manuals). This link will provide a list of product manuals arranged in alphabetical order by model number.
Crestron MC2E 2-Series Compact Control System Software License Agreement This License Agreement (“Agreement”) is a legal contract between you (either an individual or a single business entity) and Crestron Electronics, Inc. (“Crestron”) for software referenced in this guide, which includes computer software and as applicable, associated media, printed materials and “online” or electronic documentation (the “Software”).
2-Series Compact Control System Crestron MC2E If You are a business or organization, You agree that upon request from Crestron or its authorized agent, You will within thirty (30) days fully document and certify that use of any and all Software at the time of the request is in conformity with Your valid licenses from Crestron of its authorized agent.
Crestron MC2E 2-Series Compact Control System Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
2-Series Compact Control System Crestron MC2E This page is intentionally left blank. 26 • 2-Series Compact Control System: MC2E Operations Guide – DOC.
Crestron MC2E 2-Series Compact Control System This page is intentionally left blank. Operations Guide – DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations Guide – DOC. 6142A (2008091) 06.07 Specifications subject to change without notice.