Specifications
Crestron C2N-MNETGW infiNET™ Gateway/Transceiver
Operations Guide – DOC. 6317B infiNET™ Gateway/Transceiver: C2N-MNETGW • 19
NOTE: When using the C2N-MNETGW with devices that may
not be configured to support automatic channel selection (e.g.
CHV-TSTATRF when set to a fixed channel, or HTT-B10X when
running from battery power), the C2N-MNETGW must be set to
operate in fixed channel mode.
For more information, refer to the latest revision of the document
titled “Best Practices for Installation and Setup of Crestron RF
Products” (Doc. 6689).
Acquire
Devices
Crestron’s infiNET devices can communicate with a C2N-MNETGW
only if they have been acquired by that C2N-MNETGW (even if the
C2N-MNETGW and the device are operating on the same channel). To
add infiNET devices to the infiNET network, the C2N-MNETGW must
be in the Acquire mode. The Acquire mode can be activated from
Crestron Toolbox (recommended) or with the ACQUIRE button on the
C2N-MNETGW.
NOTE: The Acquire mode can be activated approximately 15 seconds
after applying power to the C2N-MNETGW.
NOTE: In an environment with multiple gateways, only one gateway
should be in the Acquire mode at a time.
NOTE: The C2N-MNETGW must be placed in the Acquire mode
before an infiNET device is placed in the Acquire mode.
Via Crestron Toolbox:
Using Crestron Toolbox to enter the Acquire mode provides the
installer with a visual account of devices as they are acquired.
1. Establish communication with the C2N-MNETGW as
described in “Establishing Communication” on page 15.
2. Select Functions | MNET Gateway... to open the
C2N-MNETGW’s controls.