Specifications

Isys™ 2.8” Handheld Wireless Touchpanel Crestron MTX-3
Uploading and Upgrading
The installer should use the latest programming software and ensure that each device
contains the latest firmware to take advantage of the most recently released features.
However, before attempting to upload or upgrade it is necessary to establish
communication. Once communication has been established, files (for example,
programs, projects or firmware) can be transferred to the control system (and/or
device). Finally, program checks can be performed (such as changing the device ID
or creating an IP table) to ensure proper functioning.
NOTE: Upgrades should be performed only by the installer.
Establishing Communication
NOTE: For PCs running Windows 2000 or XP, ActiveSync 4.5 or later is required
for Toolbox to communicate with the MTX-3 via USB to upload firmware and
display lists. Download and install ActiveSync from the Microsoft Web site
(www.microsoft.com/windowsmobile/en-us/help/synchronize/device-synch.mspx).
PCs running Windows Vista or 7™ require Windows Mobile Device Center™ for
communication with Toolbox. Download and install Windows Mobile Device Center
(WMDC) from the Microsoft Web site
(www.microsoft.com/windowsmobile/devicecenter.mspx
).
Use Crestron Toolbox for communicating with the MTX-3; refer to the Crestron
Toolbox help file for details. There are two methods of communication.
Indirect
Indirect Communication
Control System
CEN-RFGW-EX
infiNET EX
PC Running
Crestron Toolbox
LAN
or USB
Serial,
LAN
MTX-3
MTX-3 connects to the CEN-RFGW-EX (Gateway), which connects to control
system via Ethernet.
Establish communication between the PC and the control system as described in the
latest version of the 2-Series Control Systems Reference Guide (Doc. 6256).
NOTE: A USB connection between the PC and the MTX-3 is required to load
projects or firmware.
32 Isys™ 2.8” Handheld Wireless Touchpanel: MTX-3 Operations Guide – DOC. 7066B