infiNET EX Thermostat: CHV-TSTATEX Operations & Installation Guide DOC. 6989C
Setup Mode Parameters/Functions (Continued)
PARAMETER/
FUNCTION
CODE VALID VALUES
DEFAULT
VALUE
NOTES
InfiNET EX ID
(RF ID)
id 01 and 03 FE 01 Sets the infiNET EX ID. Crestron
Studio (or SIMPL Windows)
restricts infiNET EX devices to an
ID range of 03 20
infiNET EX Sleep Time SL Short (S) or Long (L) L Indicates thermostat update rate;
Setting for fewer updates (L)
conserves battery power
Start infiNET EX
Acquire
AC Not started (--)
In progress
(flashing --)
Finished, found GW
(00)
Finished, could not
find GW (E#, where
# represents an error
code)
N/A Refer to “Verifying Communication
Status” which starts on page 27 for
details
Unacquire Gateway UA Not started (--)
In progress
(flashing --)
Finished, success
(00)
Finished, failed (E#,
where # represents
an error code)
N/A Refer to “Verifying Communication
Status” which starts on page 27 for
details
Communications
check
CC Error (E# - where #
is a number from 0 to
7)
No problems (00)
N/A Refer to “Verifying Communication
Status” which starts on page 27 for
details
Check Battery Life bA Not started (--)
Estimated remaining
battery life (0 99)
N/A Gives estimated remaining battery
life in percent
Restore Factory
Defaults
Fd Not started (--)
In progress (blank or
flashing --)
Finished (00)
Button not held long
enough (Er)
N/A Restores all setup parameters to
their default settings;
To prevent accidentally performing
this action, press and hold either
the or button for three
seconds for this function to execute
Perform Heat Call Test
(Toggle)
H Not started/Heat call
off (--)
Heat call on (on)
(also, “H” icon turns
on)
N/A Tests the heat call output.
Bypasses short-cycle timers;
Useful for technician system testing;
Note that calling the heat may
activate other relays in the
thermostat as required, such as the
fan output for heat pump or
dual-fuel types
Perform Cool Call Test
(Toggle)
C Not started/Cool call
off (--)
Cool call on (on)
(also, “C” icon turns
on)
N/A Tests the cool call output;
Bypasses short-cycle timers;
Useful for technician system
testing;
Note that calling the cooling may
activate other relays in the
thermostat as required, such as the
fan output
(Continued on following page)