Installation guide
Crestron CHV-TSTATEX infiNET EX Thermostat
Operations & Installation Guide – DOC. 6989C infiNET EX Thermostat: CHV-TSTATEX
•
13
Connections for the CHV-TSTATEX
NOTE: 24 volt power is returned through the RH connector. Refer to wiring
diagrams on the following pages.
NOTE: Most heat pump systems use O for changeover. B is provided for the
systems that do not.
NOTE: Refer to “DIP Switch Setup” which starts on page 11
for DIP switch
settings.
RS2
RS1
RSR
RSR
W2
RH
B
O
G
Y2
Y/Y 1
RC
24C
W/
W
1
RS2: Remote Sensor (2) (Outdoor)
24C: 24 VAC Common
RC: Return Cool
Y/Y1: 1st Stage Compressor
Y2: 2nd Stage Compressor
G: Fan
O: Auto Change Over
B: Auto Change Over (Inverted)
RS1: Remote Sensor (1) (Indoor)
RSR: Remote Sensor Return
RSR: Remote Sensor Return
W2: 2nd Stage Heat
W/W1: 1st Stage Heat
RH: Return Heat