DIP Switch Setup
The following describes the DIP switch settings.
1. Install two AA batteries (included) in the battery compartment.
2. Locate the DIP switches inside the unit and configure the parameters per the
tables below.
DIP Switch Settings
Left Switch
# DESCRIPTION ON OFF
4 System Type Heat/Cool Heat Pump
3 Heat Pump Mode Aux Heat Dual Fuel
2 Cool/HP Stages 1 2
1 Heat Stages 1 2
Right Switch
# DESCRIPTION ON OFF
4 Fan In Heat Disabled Enabled
3 Change Over Outputs Disabled Enabled
2 Cool SP Range Normal Extended
1 N/A N/A N/A
By default, the CHV-TSTATEX is configured to be powered by two AA alkaline
batteries. To extend battery life, the device also receives power from the HVAC
system by drawing a small amount of current through the heat or cool terminals. This
is known as Steal Power mode.
To enable this feature, locate the power switch inside the unit and slide it to STEAL.
(This is the default factory setting on the CHV-TSTATEX.)
Power Switch
NOTE: Steal Power mode does not draw enough current to cause the external heat
or cool relays to close. More specifically, when the unit is not making a call for heat,
it draws power through the RH and W terminals. When the unit is making a call for
heat, it draws power through the RC and Y terminals. (This does not work if the
thermostat has been wired for a cool only application.) The CHV-TSTATEX must be
wired for heat control in order to take advantage of Steal Power mode.
ON
1 2 3 4
1 2 3 4
ON
STEAL 24VAC