Crestron CHV-TSTATEX ® infiNET EX Thermostat Operations & Installation Guide
Regulatory Compliance As of the date of manufacture, the CHV-TSTATEX has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. Federal Communications Commission (FCC) Compliance Statement CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.
Crestron CHV-TSTATEX infiNET EX Thermostat Contents infiNET EX Thermostat: CHV-TSTATEX 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Specifications .............................................................................................................. 3 Physical Description .....
Crestron CHV-TSTATEX infiNET EX Thermostat infiNET EX Thermostat: CHV-TSTATEX Introduction The CHV-TSTATEX is a wireless thermostat featuring infiNET EX® technology. The CHV-TSTATEX installs just like a conventional thermostat because no extra wires are needed to connect to the control system. Although functional as a standalone thermostat, the CHV-TSTATEX delivers enhanced functionality as part of a complete Crestron® automation system.
Crestron CHV-TSTATEX infiNET EX Thermostat infiNET EX Communications Built on steadfast infiNET technology, infiNET EX is the new standard in 2-way wireless connectivity that can handle installations in even the most urban settings. The redundant nature of its mesh networking technology means that a command is never missed, resulting in faultless operation - something that is of the utmost importance when it comes to HVAC control and home automation.
Crestron CHV-TSTATEX infiNET EX Thermostat Specifications Specifications for the CHV-TSTATEX are listed in the following table. CHV-TSTATEX Specifications SPECIFICATION DETAILS Wireless RF Transceiver 2-way RF, 2.4 GHz ISM Channels 11-26 (2400 to 2483.6 MHz), IEEE 802.15.
Crestron CHV-TSTATEX infiNET EX Thermostat CHV-TSTATEX Specifications (Continued) SPECIFICATION DETAILS Default RF ID 01 Housing Injection molded plastic, surface mountable to the front of a horizontally oriented 1-gang electrical box Dimensions Height 4.50 in (115 mm) Width 5.53 in (141 mm) Depth 1.
Crestron CHV-TSTATEX infiNET EX Thermostat Physical Description This section provides information on the connections, controls and indicators available on the CHV-TSTATEX. CHV-TSTATEX Physical View CHV-TSTATEX Overall Dimensions (Front and Side Views) 5.53 in (141 mm) 1.03 in (26 mm) 1 3 2 4 4.50 in (115 mm) 5 Operations & Installation Guide – DOC.
Crestron CHV-TSTATEX infiNET EX Thermostat CHV-TSTATEX Overall Dimensions (Rear View) 3.27 in (83 mm) CHV-TSTATEX (Connection View, front with cover removed) 6 7 6 • infiNET EX Thermostat: CHV-TSTATEX Operations & Installation Guide – DOC.
Crestron CHV-TSTATEX infiNET EX Thermostat STEAL 1 2 3 4 1 2 3 4 ON ON CHV-TSTATEX (DIP Switch and Power Switch View) 24 VAC Connectors, Controls & Indicators # CONNECTORS, CONTROLS & INDICATORS DESCRIPTION 1 MODE Button Cycles through available system modes: OFF, HEAT, AUX HEAT ONLY (for heatpump or dual-fuel systems only), AUTO and COOL 2 FAN Button Toggles fan setting between FAN AUTO and FAN ON 3 Raises the setpoint 4 Lowers the setpoint 5 LCD DISPLAY 6 HVAC Displays ambient t
Crestron CHV-TSTATEX infiNET EX Thermostat Connectors, Controls & Indicators (Continued) # CONNECTORS, CONTROLS & INDICATORS 7 HVAC DESCRIPTION (7) terminal blocks B: Auto change over (inverted); switched to RC during heat calls. O: Auto change over; switched to RC during cool calls.
Crestron CHV-TSTATEX infiNET EX Thermostat Setup Identity Code Every CHV-TSTATEX communicating via RF with a Crestron control system through a CEN-RFGW-EX wireless gateway or with an MC3 3-Series Control System requires a unique RF ID. The RF ID is a two-digit hexadecimal number that can range from 03 to FF. The RF ID of the unit, set using Crestron Toolbox™, must match the RF ID specified in the Crestron Studio or SIMPL Windows program.
Crestron CHV-TSTATEX infiNET EX Thermostat CAUTION: Excess wire pinched between the CHV-TSTATEX and electrical box could cause a short circuit. Make sure that all excess wire is completely inside the electrical box and not between the box and the CHV-TSTATEX. NOTE: To ensure accurate temperature readings, avoid drafts in the back of the unit by plugging the wire hole with insulation. 4. Make sure unit is correctly oriented and place it in the electrical box. 5.
Crestron CHV-TSTATEX infiNET EX Thermostat DIP Switch Setup The following describes the DIP switch settings. 1. Install two AA batteries (included) in the battery compartment. 2. Locate the DIP switches inside the unit and configure the parameters per the tables below.
Crestron CHV-TSTATEX infiNET EX Thermostat NOTE: In Steal Power mode, even when an auxiliary power source is available, the unit continues to enter a communications sleep state, waking every 30 seconds or 1 minute (based on the infiNET EX Sleep Time setting) to exchange data with the control system. Refer to “Remote Operation” which starts on page 32 for details. NOTE: Steal Power mode may cause problems with some types of HVAC systems, such as indicating a false heat or cool call.
Crestron CHV-TSTATEX infiNET EX Thermostat Connections for the CHV-TSTATEX RS2: Remote Sensor (2) (Outdoor) RS1: Remote Sensor (1) (Indoor) RSR: Remote Sensor Return RSR: Remote Sensor Return W2: 2nd Stage Heat W/W1: 1st Stage Heat W2 W/W 1 RH Y/Y 1 RC 24C RSR RSR Y2 O G RS2 RS1 B RH: Return Heat 24C: 24 VAC Common RC: Return Cool Y/Y1: 1st Stage Compressor Y2: 2nd Stage Compressor G: Fan O: Auto Change Over B: Auto Change Over (Inverted) NOTE: 24 volt power is returned through the RH conn
Crestron CHV-TSTATEX infiNET EX Thermostat CHV-TSTATEX in Heat Only Application 1 2 ON ON 1 2 3 4 3 4 DIP Switch Settings System C Transformer Heat Relay R Optional, for power CHV-TSTATEX in Heat Only with Fan Application 1 2 ON ON 1 2 3 4 3 4 DIP Switch Settings RH W2 W/W1 RSR RSR RS2 RS1 Fan Relay 24C RC Y/Y1 Y2 G B O Heat Relay System C Transformer R Optional, for power NOTE: To run fan during heat calls, be sure to enable the DIP switches.
Crestron CHV-TSTATEX infiNET EX Thermostat CHV-TSTATEX in Cool Only Application Y G Optional, for power 1 2 ON 1 2 C ON 3 4 3 4 DIP Switch Settings System Compressor Relay Fan Relay C Transformer R R NOTE: A jumper wire must be placed between RC to RH for in order to provide power. NOTE: Connect Y/Y1 and W/W1 to steal power in cool only mode. Make sure to disable heat calls on the Heat Enable (HE) screen in Setup mode.
Crestron CHV-TSTATEX infiNET EX Thermostat CHV-TSTATEX in Heat-Cool Application with Separate Systems C W Heat Relay R Y G C 1 2 ON ON Optional, for power 1 2 3 4 3 4 DIP Switch Settings Heat Transformer R Compressor Relay Fan Relay C Cooling Transformer R R 16 • infiNET EX Thermostat: CHV-TSTATEX Operations & Installation Guide – DOC.
Crestron CHV-TSTATEX infiNET EX Thermostat CHV-TSTATEX in Heat-Cool Application with Integrated Control Unit W Heat Relay Y Cool Relay G Fan Relay C 1 2 ON C ON Optional, for power 1 2 3 4 3 4 DIP Switch Settings System Transformer R R RH and RC must be jumpered together. Operations & Installation Guide – DOC.
Crestron CHV-TSTATEX infiNET EX Thermostat CHV-TSTATEX in Heat Pump System Application with Integrated Controller RH and RC must be jumpered together. E-U-W Aux Heat Relay O Changeover Valve Y Compressor Relay G Fan Relay 1 2 ON C ON Optional, for power 1 2 3 4 3 4 DIP Switch Settings System Transformer C R R NOTE: Heat pump and dual-fuel heat pump systems require an outdoor temperature source (such as Crestron’s CHV-RTS, sold separately) to function properly.
Crestron CHV-TSTATEX infiNET EX Thermostat CHV-TSTATEX in Dual-Fuel Heat Pump Application O Changeover Valve Y Compressor Relay G Fan Relay 1 2 ON ON C 1 2 3 4 3 4 DIP Switch Settings C System Transformer R R Optional, for power Fossil Heat System C System Transformer R NOTE: The diagram above applies where furnace control is not integrated into the heat pump system. NOTE: If the system requires a fan, set the top dip switch in the right bank to “on”.
Crestron CHV-TSTATEX infiNET EX Thermostat CHV-TSTATEX Sensor Wiring CHV-RTS 20 • infiNET EX Thermostat: CHV-TSTATEX W2 W/W1 RH 24C RSR Y2 RC RSR G Y/Y1 RS2 RS1 B O CHV-RSS Operations & Installation Guide – DOC.
Crestron CHV-TSTATEX infiNET EX Thermostat Basic Setup Basic Thermostat Setup The following describes the most common setup requirements. For full details on all setup options, refer to “Advanced Setup” which starts on page 23. Place the CHV-TSTATEX in the Setup mode by doing the following: 1. Press and hold the FAN button. 2. While the FAN button is being held, press and hold the simultaneously. 3. Hold all three buttons for 5 seconds, after which the unit enters Setup mode.
Crestron CHV-TSTATEX infiNET EX Thermostat 2. Ensure the unit is in Setup mode (refer to “Basic Thermostat Setup” which starts on page 21 or “Setup Mode” which starts on page 23) and that Acquire mode (AC) is selected. 3. Press MODE until the “infiNET EX ID” function is displayed (id). and to choose the infiNET EX ID. Use 4. Press MODE until the “Start infiNET EX Acquire” function is displayed (AC). 5.
Crestron CHV-TSTATEX infiNET EX Thermostat Advanced Setup Setup Mode After the CHV-TSTATEX is installed, it is necessary to set it up for a particular heating/cooling system. Please note that some of the setup parameters listed below are not always shown since they are dependent upon other thermostat settings. Refer to “Setup Mode Parameters/Functions” which starts on page 24 for details. Place the CHV-TSTATEX in the Setup mode by doing the following: 1. Press and hold the FAN button. 2.
Crestron CHV-TSTATEX infiNET EX Thermostat NOTE: While in Setup mode, a period of one minute with no button activity causes the CHV-TSTATEX to revert to standard operation, unless a function (such as an infiNET EX acquire) is executing. Setup Mode Parameters/Functions The following table shows the available setup parameters/functions.
Crestron CHV-TSTATEX infiNET EX Thermostat Setup Mode Parameters/Functions (Continued) PARAMETER/ FUNCTION CODE VALID VALUES DEFAULT VALUE NOTES Cool Anticipator CA 1–6 3 Lower setting results in more frequent cycles and faster response (tighter regulation); Higher setting results in less frequent cycles and slower response (looser regulation); The default value should suffice in nearly all installations Heat pump Balance Point (only appears for Heat pump and Dual-Fuel Heat pump systems) Hb 1
Crestron CHV-TSTATEX infiNET EX Thermostat Setup Mode Parameters/Functions (Continued) PARAMETER/ FUNCTION CODE VALID VALUES DEFAULT VALUE NOTES InfiNET EX ID (RF ID) id 01 and 03 – FE 01 Sets the infiNET EX ID.
Crestron CHV-TSTATEX infiNET EX Thermostat Setup Mode Parameters/Functions (Continued) PARAMETER/ FUNCTION CODE VALID VALUES DEFAULT VALUE NOTES Perform Aux Heat Call Test (Toggle) (appears only on Heat pump and Dual-Fuel Heat pump systems) A Not started/Aux call off (--) Aux call on (on) (also, “A” icon turns on) N/A Same as above, for testing aux heat output Perform Fan Call Test (Toggle) F Not started/Fan call off (--) Fan call on (on) (also, “F” icon turns on) N/A Same as above, for fan
Crestron CHV-TSTATEX infiNET EX Thermostat Self-Test Results These status/error codes are returned when performing a self-test operation, enter Setup mode as described in “Basic Setup” on page 21. Press MODE until the St or on the CHV-TSTATEX to verify the function is displayed. Press communication status.
Crestron CHV-TSTATEX infiNET EX Thermostat Operation System Mode The MODE button on the CHV-TSTATEX cycles the unit through all available system modes in the following order: Off, Heat, Emergency Heat (for heat pump and dual-fuel systems), Cool and Auto (if enabled in Setup). The system mode changes upon release of the MODE button and the selected mode becomes operational 5 seconds after the mode has been entered. Off Mode In Off mode, all HVAC systems are disabled.
Crestron CHV-TSTATEX infiNET EX Thermostat either the flame or snowflake icon to flash rapidly. This or indicates which setpoint is adjusted by subsequent presses of the buttons. To adjust or view the alternate setpoint, press the MODE button while the icon is flashing. This causes the alternate icon to flash and buttons adjust that setpoint. The flashing icon and now the times out after 5 seconds of no button activity. b. In single setpoint Auto mode, use the buttons to adjust the setpoint as usual.
Crestron CHV-TSTATEX infiNET EX Thermostat makes a heat call or auxiliary heat call (if the DIP switch is set to Enabled). When set to ON the fan always runs. Setpoints The setpoint is the user selectable temperature for the system to maintain. and buttons change the current setpoint by one degree F or C (if The Temperature Scale is set to F or C1) or by one half degree C (if Temperature Scale is set to C2).
Crestron CHV-TSTATEX infiNET EX Thermostat Remote Operation As an infiNET EX device, the CHV-TSTATEX can be controlled remotely via a Crestron control system. Most often, control of the thermostat is achieved via a touch screen or Web-based graphical interface. In order to extend battery life, the thermostat only communicates with the control system once every 30 seconds or 1 minute, based on the infiNET EX Sleep Time setting.
Crestron CHV-TSTATEX infiNET EX Thermostat LCD Display Elements # LCD DISPLAY ELEMENT DESCRIPTION 1 Large 7-segment digits Indicates current ambient temperature ; In Setup mode, indicates current setup parameter/function; Display range is limited to –9º to 99º F (-9º to 43º C); If the ambient temperature is above 99º, the display indicates 99º; If the ambient temperature is below –9º, the display indicates –9º 2 Small 7-segment digits Indicates current setpoint (in F or C) in whole degrees; While
Crestron CHV-TSTATEX infiNET EX Thermostat Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. Once communication has been established, files (for example, programs or firmware) can be transferred to the control system (or device).
Crestron CHV-TSTATEX infiNET EX Thermostat Crestron Studio / SIMPL Windows If a Crestron Studio (or SIMPL Windows) program is provided, it can be uploaded to the control system using Crestron Studio (or SIMPL Windows) or Crestron Toolbox. Firmware Check the Crestron Web site to find the latest firmware. (New users must register to obtain access to certain areas of the site, including the FTP site.) Upgrade CHV-TSTATEX firmware via Crestron Toolbox. 1.
Crestron CHV-TSTATEX infiNET EX Thermostat Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. CHV-TSTATEX Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION No power from system. Check for +24 V on 24C connector. Check circuit breaker powering furnace or boiler. Check thermostat wiring. Check batteries (if running on battery power).
Crestron CHV-TSTATEX infiNET EX Thermostat CHV-TSTATEX Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION System cycles too quickly. Anticipator setting is too low. Reprogram anticipator setting (refer to “Setup Mode Parameters/Functions” which starts on page 24). Poor battery life. Ensure that the power switch selection position is proper for the expected conditions.
Crestron CHV-TSTATEX infiNET EX Thermostat CHV-TSTATEX Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Heat or cool call occurs but device does not indicate a heat or cool call. Steal power function may be causing problems with HVAC system. Change Power DIP Switch to 24VAC and ensure two AA batteries are installed. Improper wiring connections. Recheck wiring connections. Auto mode is disabled in setup.
Crestron CHV-TSTATEX infiNET EX Thermostat Appendix: About Heat Pumps A heat pump extracts available heat from one area and transfers it to another. Even cold air contains some heat and heat pumps can extract heat from the outside air on a cold day and transfer it indoors to maintain a comfortable temperature. A heat pump also works in reverse during the summer, extracting heat from indoors and transferring it outdoors.
Crestron CHV-TSTATEX infiNET EX Thermostat Glossary Anticipators Used to anticipate the drop or rise in temperature and energize the appropriate system before reaching the set point. Anticipators affect how tightly the setpoint temperature is maintained. Auto Dead Band Sets the minimum separation in auto mode between heat and cool setpoints (with dual setpoints) or maximum drift before system latches alternate mode (with single setpoint).
Crestron CHV-TSTATEX infiNET EX Thermostat Humidity The total amount of moisture in air. Relative humidity (RH) is the amount of moisture in air, relative to its total capability based upon its temperature (dew point). Moisture condenses on surfaces that are below this dew point. HVAC Heating, ventilation and air conditioning. Interstage Differential The proportional temperature error (0.5 to 3.0º) to trigger the second stage (2-stage only), such as the aux heat for a heat pump type system.
Crestron CHV-TSTATEX infiNET EX Thermostat Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from Crestron. To obtain warranty service for Crestron products, contact an authorized Crestron dealer. Only authorized Crestron dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
Crestron CHV-TSTATEX infiNET EX Thermostat This This page page is is intentionally intentionally left left blank. blank. Operations & Installation Guide – DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations & Installation Guide – DOC. 6989C (2027560) 01.13 Specifications subject to change without notice.