GREEN LIGHT® EXPRESS Power Switching Cabinet GLPX-HSW-FT Introduction CRESTRON GREEN LIGHT EXPRESS power switching cabinets come pre-configured with GLXP switching modules already installed. The cabinets only require installation and wiring of feed and load circuits. Regulatory Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT® EXPRESS Physical Description This section shows the dimensions of the CRESTRON GREEN LIGHT EXPRESS power switching cabinets.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPX-HSW-FT Dimensions of GLPX-HSW-FT-8 , -12, -16 Power Switching Cabinets (Internal View) 2 1/4” (58 mm) (2X) Ø 5/16” (Ø 8 mm) MOUNTING HOLES 10 7/8” (276 mm) 2 1/8” (55 mm) (2x) 11/16” (19 mm) (2x) Ø 5/8” (Ø 16 mm) 23 1/2" (597 mm) 18 15/16” (481 mm) SERVICE SCREWDRIVER * TIE WRAP HOLDERS (MAY BE MOVED TO OTHER HOLES AS REQUIRED) (2X) Ø 7/16 (Ø 12 mm) MOUNTING HOLES * Installed GLXP modules come with additional tie wrap holders.
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT® EXPRESS Dimensions of GLPX-HSW-FT-20, -24, -28, -32 Power Switching Cabinets (Front, Side and Bottom View) 39 5/8” (1 m) KNOCKOUT FOR 3/4” (20 mm) CONDUIT (TYPICAL BOTH SIDES) 3 1/16” (78 mm) 1/4” (7 mm) 3 1/4” (83 mm) 4 7/16” (113 mm) 16 1/8” (409 mm) 2 1/2” (64 mm) 1 1/4” (32 mm) 14 3/8" (365 mm) 4 • GREEN LIGHT® EXPRESS Power Switching Cabinet GLPX-HSW-FT Installation Guide – DOC.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPX-HSW-FT Dimensions of GLPX-HSW-FT-20, -24, -28, -32 Power Switching Cabinets (Internal View) 2 1/4” (58 mm) (2X) Ø 5/16” (Ø 8 mm) MOUNTING HOLES 10 7/8” (276 mm) 2 1/8” (55 mm) GROUND LUG (2x) 11/16” (19 mm) (2x) Ø 5/8” (Ø 16 mm) 38 7/8” (998 mm) 34 3/8” (873 mm) SERVICE SCREWDRIVER * TIE WRAP HOLDERS (MAY BE MOVED TO OTHER HOLES AS REQUIRED) (2X) Ø 7/16 (Ø 12 mm) MOUNTING HOLES * Installed GLXP modules come with additional tie wrap holder
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPX-HSW-FT Installation Observe the following when installing the cabinet: • The cabinet must be mounted by a licensed electrician in accordance with all national and local codes. Refer to the diagram below for specific requirements. • The cabinet is designed for surface mounting on a wall. • Cabinets are intended for indoor use only. • The ambient temperature range should be 32°F to 104°F (0°C to 40°C).
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPX-HSW-FT Wiring NOTE: All wiring must be installed in accordance with all local and national electrical codes. NOTE: Refer to the torque settings specified on pages 8 and 9. CRESTRON GREEN LIGHT EXPRESS cabinets are shipped with GLXP low profile switching modules installed.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPX-HSW-FT Feed-Through and Load Wiring (Section A) CAUTION: Bypass jumpers are provided on each output to allow testing and to protect the modules during installation. The jumper shorts the L and SW terminals so that the load circuit is energized when the branch breaker is on. NOTE: Do not remove the bypass jumper until all feed and load wiring has been completed, and the circuits have been tested for electrical faults.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPX-HSW-FT Control Wiring (Section B) The bottom of the cabinet contains Cresnet® connections for interfacing to the rest of the Crestron® control system, and a power port to provide an alternate source of 24 volt power to the modules. It also provides an override input which can be tied to devices such as the GLS-PLS-120/277 phase-loss sensor, or other devices that provide a dry contact closure (manual switch, fire alarm relay, etc.).
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT® EXPRESS NET Port Wiring When wiring the supplied NET connectors for connection to a Crestron control system or other device on the Cresnet network, use Crestron certified wire such as CRESNET-NP or CRESNET-P. To ensure optimum performance over the full range of your installation topology, use Crestron certified wire.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPX-HSW-FT Testing Manual Control Lighting modules can be manually controlled from the front panel. To toggle the output between off and on, tap the appropriate ON/OFF button. The corresponding LED illuminates and the output state is shown on the NET ID display (“oF” for off, “On” for on) for two seconds after the button is released. NOTE: The control system program may change the settings if the Override mode is not enabled.
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT® EXPRESS Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. Troubleshooting TROUBLE Module(s) does not function. POSSIBLE CAUSE(S) CORRECTIVE ACTION Power not delivered to the module.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPX-HSW-FT Appendix A: Setting Module Net IDs The following procedure will normally be performed by an authorized Crestron representative as part of the System Commissioning phase. For system wiring and basic testing as described on pages 7 and 11, it is not necessary to perform this step.
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT® EXPRESS Appendix B: Specifications Specifications for the GLXP modules are listed in the following table.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPX-HSW-FT This page is intentionally left blank. Installation Guide – DOC.
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT® EXPRESS Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.