GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Introduction CRESTRON GREEN LIGHT EXPRESS power switching cabinets come pre-configured with GLXX switching modules already installed. The cabinets only require installation and wiring of feed and load circuits. Regulatory Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
Power Switching Cabinet GLPS-HDSW-FT CRESTRON GREEN LIGHT® EXPRESS Physical Description This section shows the dimensions of the CRESTRON GREEN LIGHT EXPRESS power switching cabinets.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Dimensions of GLPS-HDSW-FT-8, -12, -16, -20, -24 (shown below) Power Switching Cabinets (Internal View) 2 1/4” (2X) Ø 5/16” (58 mm) (Ø 8 mm) 10 7/8” MOUNTING HOLES (276 mm) 2 1/8” (55 mm) (2x) 11/16” (19 mm) (2x) Ø 5/8” (Ø 16 mm) * TIE WRAP HOLDERS (MAY BE MOVED TO OTHER HOLES AS REQUIRED) 23 1/2" (597 mm) 18 15/16” (481 mm) SERVICE SCREWDRIVER (2X) Ø 7/16 (Ø 12 mm) MOUNTING HOLES * Installed GLXX modules come with additional tie wra
Power Switching Cabinet GLPS-HDSW-FT CRESTRON GREEN LIGHT® EXPRESS Dimensions of GLPS-HDSW-FT-28, -32, -36, -40, -48, -52, -56 Power Switching Cabinets (Front, Side and Bottom View) 39 5/8” (1 m) KNOCKOUT FOR 3/4” (20 mm) CONDUIT (TYPICAL BOTH SIDES) 3 1/16” (78 mm) 1/4” (7 mm) 3 1/4” (83 mm) 4 7/16” (113 mm) 16 1/8” (409 mm) 2 1/2” (64 mm) 1 1/4” (32 mm) 14 3/8" (365 mm) 4 • GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Installation Guide – DOC.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Dimensions of GLPS-HDSW-FT–28, -32, -36, -40, -48,-52, -56 (shown below) Power Switching Cabinets (Internal View) 2 1/4” (58 mm) (2X) Ø 5/16” (Ø 8 mm) MOUNTING HOLES 10 7/8” (276 mm) GROUND LUG 2 1/8” (55 mm) (2x) 11/16” (19 mm) (2x) Ø 5/8” (Ø 16 mm) 38 7/8” (998 mm) * TIE WRAP HOLDERS (MAY BE MOVED TO OTHER HOLES AS REQUIRED) 34 3/8” (873 mm) SERVICE SCREWDRIVER (2X) Ø 7/16 (Ø 12 mm) MOUNTING HOLES * Installed GLXX modules come
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Installation Observe the following when installing the cabinet: • The cabinet must be mounted by a licensed electrician in accordance with all national and local codes. Refer to the diagram below for specific requirements. • The cabinet is designed for surface mounting on a wall. • Cabinets are intended for indoor use only. • The ambient temperature range should be 32°F to 104°F (0°C to 40°C).
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Wiring NOTE: All wiring must be installed in accordance with all local and national electrical codes. NOTE: Refer to the torque settings specified on pages 8 and 9. CRESTRON GREEN LIGHT EXPRESS power switching cabinets come pre-configured with GLXX-HDSW switching modules already installed. The cabinets only require installation and wiring of feed and load circuits.
Power Switching Cabinet GLPS-HDSW-FT CRESTRON GREEN LIGHT® EXPRESS Feed-Through and Load Wiring (Section A) NOTE: Use copper conductors only – rated 75°C. Wire Gauge and Torque Values TERMINAL CONNECTOR MAX WIRE RANGE TORQUE STRIP LENGTH INPUT 26-10 AWG 5.31 lb-in (0.6 Nm) to 7.08 lb-in (0.8 Nm) max 3/8” (9 mm) OUTPUT/CONTACT 26-10 AWG 5.31 lb-in (0.6 Nm) to 7.08 lb-in (0.8 Nm) max 3/8” (9 mm) GROUND LUG 14-4 AWG 25-45 lb-in (2.8-5.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Control Wiring (Section B) The bottom of the cabinet contains Cresnet® connections for interfacing to the rest of the Crestron® control system. It also provides overrides input which can be tied to devices such as the GLS-PLS-120/277 phase-loss sensor, or other devices that provide a dry contact closure (manual switch, fire alarm relay, etc.).
Power Switching Cabinet GLPS-HDSW-FT CRESTRON GREEN LIGHT® EXPRESS NET Port Wiring When wiring the supplied NET connectors for connection to a Crestron control system or other device on the Cresnet network, use Crestron certified wire such as CRESNET-NP or CRESNET-P. For instructions on network wiring, refer to “Appendix C: Network Wiring” on page 18. When daisy-chaining connections between NET ports, strip the ends of the wires carefully to avoid nicking the conductors.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Relays The GLXX-CTRL identifies relays in the sequential order in which they are introduced to the GLXX-HDSW. Relays come pre-installed from the factory. Install additional relays from left to right, starting the top of the cabinet and moving down. Refer to the illustration below. Relay Installation Sequence 1 2 3 4 SERVICE SCREWDRIVER Installation Guide – DOC.
Power Switching Cabinet GLPS-HDSW-FT CRESTRON GREEN LIGHT® EXPRESS Relay Installation Procedure 1. Insert the output side of the relay into the tab(s) on the mounting strap. 2. Push down on the relay to lock the spring clips into the relay. Refer to the illustration below. Inserting the relay into the mounting strap (Double Pole Relay Shown) Push Tabs Spring Clips 3. Attach the wiring connector on the relay to the GLXX-HDSW.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Relay Removal Procedure 1. Disconnect the wiring connector on the relay from the GLXX-HDSW. Disconnecting the Relay from the GLXX-HDSW (Single Pole Relay Shown) 2. To release the relay from the mounting strap, press firmly on the spring clip(s). 3. Pull the relay away from the tabs and lift it out of the mounting strap Removing the relay from the mounting strap (Double Pole Relay Shown) Press Down Tabs Installation Guide – DOC.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Testing Manual Control Lighting loads can be manually controlled from the front panel. RED LED ILLUMINATES WHEN LOCAL CONTROL IS ENABLED USE UP/DOWN ARROWS TO SELECT RELAY TO CONTROL (NET ID WILL DISPLAY RELAY NUMBER) TOGGLES LOCAL CONTROL ON/OFF TOGGLES SELECTED RELAY ON/OFF NOTE: To disable local control, press the ENABLE button again or wait for two minutes. The red LED beside the button will deactivate.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. Troubleshooting TROUBLE Module(s) does not function. Unit cannot be taken out of Override mode POSSIBLE CAUSE(S) CORRECTIVE ACTION Device is not receiving power from a Crestron power source. Verify connections.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Appendix A: Setting Module Net IDs The following procedure will normally be performed by an authorized Crestron representative as part of the System Commissioning phase. For system wiring and basic testing as described on pages 7 and 14, it is not necessary to perform this step.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Appendix B: Specifications Specifications for the GLXX-HDSW modules are listed in the following table.
Power Switching Cabinet GLPS-HDSW-FT CRESTRON GREEN LIGHT® EXPRESS Appendix C: Network Wiring Check Network Wiring Use the Right Wire In order to ensure optimum performance over the full range of your installation topology, Crestron Certified Wire and only Crestron Certified Wire may be used. Failure to do so may incur additional charges if support is required to identify performance deficiencies because of using improper wire.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT Crestron Network Interconnect Diagram Pair A 22 AWG Twisted Blue = Z White = Y Shield To Control System To Network Device G 24 Z Y Y Z 24 G Front View Green Front View Pair B 18 AWG Parallel Black = Ground Red = 24 VDC Green CAUTION: Possible Equipment Damage if Miswired Do not power up system until all wiring is verified. Care should be taken to ensure Data (Y & Z), and Power (24 & G) connections are not crossed.
Power Switching Cabinet GLPS-HDSW-FT CRESTRON GREEN LIGHT® EXPRESS Crestron Network to Mini Network Interconnect Diagram Wire Nuts & Jumper Wires Pair A 22 AWG Twisted Blue = Z White = Y To Control System Black G Shield* To Mini Network Device 24 Blue Y Z White Y Z G 24 Red Front View Green Front View Pair B 18 AWG Parallel Black = Ground Red = 24 VDC Black CAUTION: Possible Equipment Damage if Miswired Do not power up system until all wiring is verified.
CRESTRON GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT This page is intentionally left blank. Installation Guide – DOC.
Power Switching Cabinet GLPS-HDSW-FT CRESTRON GREEN LIGHT® EXPRESS Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.