Crestron GLS-EM-MCU ® Crestron Green Light Power Meter Control Unit Operations Guide
This document was prepared and written by the Technical Documentation department at: Regulatory Compliance This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc. As of the date of manufacture, the GLS-EM-MCU has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. Federal Communications Commission (FCC) Compliance Statement This device complies with part 15 of the FCC Rules.
Crestron GLS-EM-MCU Crestron Green Light® Power Meter Control Unit Contents Crestron Green Light® Power Meter Control Unit: GLS-EM-MCU 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Applications..............................................................................................
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU ® Crestron Green Light Power Meter Control Unit: GLS-EM-MCU Introduction The GLS-EM-MCU is an Ethernet-based power metering control unit, designed to log overall electricity usage in real time. It measures and tracks actual energy consumption by attaching to the incoming electrical service and branch circuits.
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU around the feed wire of each circuit, and then connected to the GLS-EM-CTI current transformer interfaces. Up to four GLS-EM-CTI can connect to a single GLS-EM-MCU for monitoring of up to 84 branch circuits. Current Transformers Current transformers are vital to metering power. Crestron® offers various split-core models that work with 600, 400, and 200 Amp feeds; these devices clamp around main feeds.
Crestron GLS-EM-MCU Crestron Green Light® Power Meter Control Unit Applications The following diagram shows a GLS-EM-MCU in a typical application. GLS-EM-MCU in a Typical Application Operations Guide – DOC.
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU Specifications Specifications for the GLS-EM-MCU are listed in the following table.
Crestron GLS-EM-MCU Crestron Green Light® Power Meter Control Unit Physical Description This section provides information on the connections, controls and indicators available on the GLS-EM-MCU. GLS-EM-MCU Physical View Operations Guide – DOC.
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU GLS-EM-MCU Overall Dimensions (8x) Ø 3/16 in (Ø 6 mm) Wall Mounting Holes for #8 or #10 Screws (Not Supplied) 10 3/16 in (260 mm) 10 1/4 in (260 mm) 7 3/4 in (196 mm) Both Ends 7 in (178 mm) Both Ends 3 3/4 in (96 mm) Both Ends 3/8 in (10 mm) 1 1/4 in (32 mm) 10 1/8 in (257 mm) 2 11/16 in (69 mm) 1 11/16 in (43 mm) 6 in (153 mm) Both Ends 2 1/16 in (53 mm) 2 7/16 in (62 mm) 2 in (51 mm) 3 3/16 in (81 mm) 3 7/16 in (88 mm) 1
Crestron GLS-EM-MCU Crestron Green Light® Power Meter Control Unit GLS-EM-MCU Overall Dimensions (Cover Removed) (4x) Ø 1/4 in (Ø 7 mm) Wall Mounting Holes for #10 Screws (Not Supplied) Ground Bus All Mating Connectors Furnished with Unit 7 1/8 in (181 mm) 10 1/8 in (257 mm) 1 1/2 in (38 mm) 1 9/16 in (40 mm) Operations Guide – DOC.
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU Connectors, Controls & Indicators Connectors, Controls & Indicators # CONNECTORS*, CONTROLS & INDICATORS 1 NEUT 2 LINE1 – LINE3 3 CT1 – CT3 4 BRANCH CIRCUIT MONITORS DESCRIPTION (1) terminal block, neutral input (3) terminal blocks, line input for each of three separate phases (3) 2-pin detachable terminal block, input for main leg current transformer (1) 8-pin detachable terminal block to be attached to a current transformer
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU Connectors, Controls & Indicators (Continued) * Operations Guide – DOC. 7294B # CONNECTORS*, CONTROLS & INDICATORS DESCRIPTION 5 LINE1 – LINE3 LEDs (3) Green LEDs, indicate line voltage is present on each input LINE1 through LINE3 CT1 – CT3 LEDs (3) Green LEDs, indicate current is flowing through CTs connected to ports CT1 through CT3 6 PULSE INPUTS 1-4 (1) 8-pin 3.
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU Setup Identity Code The IP ID is set within the GLS-EM-MCU’s IP table using Crestron Toolbox™. For information on setting an IP table, refer to the Crestron Toolbox help file. The IP IDs of multiple GLS-EM-MCU devices in the same system must be unique. When setting the IP ID, consider the following: • The IP ID of each unit must match an IP ID specified in the SIMPL Windows program.
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU Programming Software Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be viewed in the Online Help section of the Crestron Web site. To post a question or view questions submitted to Crestron’s True Blue Support, log in at www.crestron.com/onlinehelp. First-time users must establish a user account to fully benefit from all available features.
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU 2. If additional GLS-EM-MCU devices are to be added, repeat step 1 for each device. Each GLS-EM-MCU is assigned a different IP ID number as it is added. 3. If necessary, double click a device to open the “Device Settings” window and change the IP ID, as shown in the following illustration. “Device Settings: Crestron GLS-EM-MCU” Window NOTE: The ID code specified in the SIMPL Windows program must match the IP ID of each unit.
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. Once communication has been established, files (for example, programs or firmware) can be transferred to the control system (and/or device).
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU 8-pin RJ-45 connectors. Alternatively, use a CAT5 crossover cable to connect the two LAN ports directly without using a hub or router. 3. Use the Device Discovery Tool in Crestron Toolbox to detect all Ethernet devices on the network and their IP configuration. The tool is available in Toolbox version 1.15.143 or later. 4.
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU Configuration Configuration of the GLS-EM-MCU system is done using the GLS Energy Meter Configuration Tool in Crestron Toolbox version 2.31, or later. Click Tools | GLS , to open the configuration tool. Energy Meter Configuration Tool, or click Refer to the applications help file for detailed information about the function of specific buttons.
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. GLS-EM-MCU Troubleshooting TROUBLE Device does not function. CT1 – CT3 LED is flashing. Loss of functionality due to electrostatic discharge. POSSIBLE CAUSE(S) CORRECTIVE ACTION Device is not communicating with the network.
Crestron GLS-EM-MCU Crestron Green Light® Power Meter Control Unit Future Updates As Crestron improves functions, adds new features and extends the capabilities of the GLS-EM-MCU, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision. Check the Crestron Web site periodically for manual update availability and its relevance.
Crestron Green Light® Power Meter Control Unit Crestron GLS-EM-MCU Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from Crestron. To obtain warranty service for Crestron products, contact an authorized Crestron dealer. Only authorized Crestron dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.