Specifications

Crestron e-Schedule Programmer’s Guide
Cfg_System_Variables
Field Name Description
GlobalSafeChannel The default television channel for the entire
e-Schedule system, both at startup and at the end
of a scheduled event, taken from the ChannelId
field of Cfg_Hardware_LegalChannels.
BasebandOrBroadband 0 = Baseband; 1 = Broadband.
Destination Devices
Cfg_Hardware_SetTopBox
Field Name Description
SetTopBoxId The ID number of the set-top box (room
controller)—must be the same as the
SubLocationId.
SubLocationId The ID number of the room where the set-top box
is located, taken from Cfg_Area_SubLocations.
RealTimeMachineID Taken from Cfg_Hardware_RealTimeMachine,
this ID number must be “1”.
IPAddress The static IPAddress of the set-top box or control
system, if set-top box does not have its own IP
Address.
IPID The decimal equivalent of the hexadecimal Cresnet
IP ID of the set-top box.
SetTopBoxType Type of controller, i.e., CEN-TVAV, taken from
Cfg_Hardware_SetTopBox_Variables.
SwitcherID In baseband systems only, this is the ID number of
the head end switcher, taken from
Cfg_Hardware_Switcher.
SwitcherOutput In baseband systems only, this is the switcher
output ID number that is specified in SIMPL
Windows.
SafeChannel Overrides the global (default) safe channel defined
in Cfg_System_Variables (–1 = Use Global Safe
Channel)—currently unused.
Enable Check box to enable or “remove” the device in the
system.
Programmer’s Guide e-Schedule – DOC. 5919 17