Specifications

Software Development Kit & CNX Gateway Crestron e-control™
“Reply from address <ip-address>…”. If you are running on an
“isolated network” (i.e., a network that contains only your PC and the
CNMSX equipment and is not connected to the larger intranet) and do
not get a response from the “ping” to the IP address of the CNMSX, go
back to the previous steps to see if you can find an error.
C:\WINDOWS>ping 132.149.2.2
Pinging 132.149.2.2 with 32 bytes of data:
Reply from 132.149.2.2: bytes=32 time=8ms TTL=60
Reply from 132.149.2.2: bytes=32 time=5ms TTL=60
Reply from 132.149.2.2: bytes=32 time=5ms TTL=60
Reply from 132.149.2.2: bytes=32 time=5ms TTL=60
Hardware Setup of CEN Series Devices
If you are working with the CEN-IO network interface device, follow these steps to
enable CIP communications in your CEN-IO. This will allow the CEN-IO to
communicate directly to a CNX control system, or directly to a browser or VB app
using the Crestron e-control SDK.
1. Check the firmware version in each CEN-IO by following the steps
described in the CEN-IO manual. If the version is v1.2 or later, you can
skip the next two steps; your CEN-IO is already TCP/IP enabled.
2. Update the firmware as described in the CEN-IO manual (latest
revision of Doc. 5718). Consult Crestron Technical support
(1.888.CRESTRON [1.888.273.7876]) to obtain the proper firmware
version.
3. Assign an IP address, subnet mask and gateway as described in the
CEN-IO manual.
Leading Specifications
Specifications Table
DETAILS
CNX Gateway Version 2.08 or later
SDK Version 1.3.6 or later
Web Server Refer to "Configure the Web Server"
CNMSX-AV/PRO Upgrade File (upz) Version 5.09.02x or later*
CNRACKX/-DP Upgrade File (upz) Version 5.09.02 or later*
CEN-IO Firmware
Version 1.2 or later
SIMPL™ Windows
®
Version 1.21.03 or later
Visual Basic Version 5.0 or later
Netscape Navigator Version 4.5 or later
Internet Explorer Version 5.0 or later
SPECIFICATIONS
*
CNX upgrade files are required for either CNMSX-AV/PRO or CNRACKX/-DP. Filenames for
upgrade files have a UPZ extension and can be obtained from the Downloads page (OPSYS Library)
of the Crestron website (
www.crestron.com). New users are required to register in order to
obtain access to the FTP site.
8 Crestron e-control™: Software Development Kit & CNX Gateway Operations Guide - DOC. 5778A