Installation guide
Interface Module    Crestron TPS-6X-IMCW 
NOTE: All Crestron certified Cresnet wiring must consist of two 
twisted pairs. One twisted pair is the +24V conductor and the GND 
conductor and the other twisted pair is the Y conductor and the Z 
conductor. 
Strip and Tin 
Wire 
When daisy-chaining Cresnet units, strip the ends of the wires carefully 
to avoid nicking the conductors. Twist together the ends of the wires that 
share a pin on the network connector and tin the twisted connection. 
Apply solder only to the ends of the twisted wires. Avoid tinning too far 
up the wires or the end becomes brittle. Insert the tinned connection into 
the Cresnet connector and tighten the retaining screw. Repeat the 
procedure for the other three conductors. 
Add Hubs 
For larger networks (i.e., greater than 28 network devices), it may 
become necessary to add a Cresnet Hub/Repeater (CNXHUB) to 
maintain signal quality throughout the network. Also, for networks with 
lengthy cable runs it may be necessary to add a Hub/Repeater after only 
20 devices. 
Further Inquiries 
If you cannot locate specific information or have questions after 
reviewing this guide, please take advantage of Crestron's award winning 
customer service team by calling Crestron at 1-888-CRESTRON 
[1-888-273-7876]. 
You can also log onto the online help section of the Crestron website 
(www.crestron.com/onlinehelp
) to ask questions about Crestron products. 
First-time users will need to establish a user account to fully benefit from 
all available features. 
Future Updates 
As Crestron improves functions, adds new features and extends the 
capabilities of the TPS-6X-IMCW, additional information may be made 
available as manual updates. These updates are solely electronic and 
serve as intermediary supplements prior to the release of a complete 
technical documentation revision. 
Check the Crestron website periodically for manual update availability 
and its relevance. Updates are identified as an “Addendum” in the 
Download column. 
18 • Interface Module: TPS-6X-IMCW  Installation Guide – DOC. 6874B 