Specifications
DigitalMedia Switchers Crestron DM-MD8X8/16X16/32X32
40
•
DigitalMedia Switchers: DM-MD8X8/16X16/32X32 Operations Guide – DOC. 6755D
NOTE: The actual configuration of the output cards are specified during ordering.
For details on output connections, refer to “Output Connections” on page 82.
NOTE: Ensure the unit is properly grounded by connecting the chassis ground lug
to an earth ground (building steel).
NOTE: For optimum performance, Crestron strongly recommends using DM cable
or CresFiber, available from Crestron. Other high-quality fiber optic cable (such as
InfiniCor300) may also be used with varying performance.
NOTE: When using fiber, it is recommended that you have at least two spare fibers
for each location. DM fiber components use SC multimode connectors.
DMNet Power
Devices connected to each DMNet port can receive power from the DM switcher’s
internal power supply or from an external power supply such as the C2N-SPWS300.
The DMNet ports are preconfigured for operation using the DM switcher’s internal
power supply.
To power a DMNet port externally from a Cresnet 24 VDC power supply, connect
the power supply to the E (External) and G (Ground) pins on the EIG connector as
shown in the following diagram.
Providing DMNet Power Externally
24 G
Creston 24 VDC
Power Supply
To power a DMNet port using the DM switcher’s internal power supply, install a
jumper on the EIG connector from the E (External) pin to the I (Internal) pin as
shown in the following diagram.
Providing DMNet Power Internally
Label the Buttons
Use Crestron Engraver software to print custom labels for the DM switcher’s front
panel buttons and LEDS. Crestron recommends printing on 100-pound paper. Paper
with a weight less than 100 pounds will tend to crumple while sliding in, while paper
with a weight of more than 100 pounds may not fit.