Specifications

Crestron CSA-PWS10S-HUB Power Supply for Crestron Shade Motors
CSA-PWS10S-HUB Specifications (Continued)
SPECIFICATION DETAILS
Input Terminal
(CSA-PWS10S-HUB-CAEN-
1X1 only)
1810 AWG, 30 A, 600 V
Line Power
CSA-PWS10S-HUB
(1) Attached input power cable (~10 in long (254 mm)) with inline IEC 60320 C14
main power inlet;
Mates with removable power cord (included)
CSA-PWS10S-HUB-
CAEN-1X1
(1) Attached input power cable (~10 in long (254 mm)) with inline IEC 60320 C14
main power inlet;
Connects to ac power source using grounded pigtail cable and terminal block
(both included)
Cresnet
®
(2) 4-pin 5 mm detachable terminal blocks (Cresnet connectors included);
Cresnet slave ports, paralleled;
Connect to Cresnet control network, power not supplied to these connections;
Cresnet power output ports with data pass-through;
In event of power failure the unit is auxiliary powered from this port to provide
status
A-E, 1-10 (10) 4-pin 5 mm detachable terminal blocks comprising (2) Cresnet ports per
each of (5) hub segments (Cresnet connectors included);
Each terminal bock provides 24 volts and 50 watts LPS
USB (1) USB Type B female, USB computer console port
LEDs
PWR 1-10
(10) Green LEDs, indicate 24 V present at each corresponding output;
Indicates over current situation
NET A-E (5) Amber LEDs, indicate Cresnet activity on each corresponding segment;
Indicates issues on the bus during diagnostic testing
NET HOST (1) Amber LED, indicates activity on the Cresnet bus
MSG (1) Red LED, indicates error messages and test mode
Push Buttons
MASTER UP
MASTER DOWN
TEST
RESET
(1) Push button, press and hold to raise all connected shades
(1) Push button, press and hold to lower all connected shades
(1) Push button, initiates diagnostic test
(1) Recessed push button, forces hardware reset
2 Power Supply for Crestron Shade Motors: CSA-PWS10S-HUB Installation Guide DOC. 7438C