System information

Crestron 3-Series Control Systems Reference Guide
Reference Guide DOC. 7150A 3-Series Control Systems 57
Control System IP Table
IP table information can be entered in one of two ways. The first method creates
what is referred to as a default IP table based on information given in the SIMPL
Windows program. The second method uses Crestron Toolbox to manage the IP
table.
NOTE: IP tables used in Ethernet-based Master-Slave applications have their own
IP table requirements. Refer to “Master-Slave Modeon page 30 for details.
Creating the Default IP Table from SIMPL Windows
While adding Ethernet devices (Ethernet slave processors, Ethernet-enabled touch
screens, Ethernet devices, or Ethernet modules), the IP information for each device
must be entered in Configuration Manager to determine the information contained in
the default IP table.
1. Double-click the Ethernet device in the SIMPL Windows Configuration
Managerscreen to open the “Device Settings” window.
2. Select the IP Net Address tab.