System information
Crestron 3-Series Control Systems Reference Guide
Reference Guide – DOC. 7150A 3-Series Control Systems • 9
Once the system information is displayed a variety of functions are available to the
user. For more information, refer to the Crestron Toolbox help file.
TCP/IP Connection
NOTE: DHCP is enabled by default in 3-Series Control Systems. Crestron Toolbox
autodiscover can be used if the control system has access to the DHCP server.
Before communicating with an Ethernet-enabled control system over TCP/IP, a static
IP address or the address/host name of the DHCP server (if DHCP is to be used)
must be obtained from the network administrator. The USB connection previously
described must be used to configure the unit’s TCP/IP settings. After configuring the
IP information of the control system, further communications can be done over
TCP/IP. For more information, refer to the Crestron e-Control Reference Guide
(Doc. 6052) at
www.crestron.com/manuals.
1. Select Functions | Ethernet Addressing… to open the “Ethernet
Addressing” window.
“Ethernet Addressing” Window
2. Enable TCP/IP communications by checking Enable Ethernet and configure
for static or dynamic IP operation.
a) Configure for static IP Operation
i. Clear (de-select) the Enable DHCP check box.