Updating the modules
Changes in the major or minor revision number are likely to have interface changes
that can affect an existing program, and new inputs and outputs might need
reconciling. Depending on the subset of the signals used in the installation, these
new controls can often be ignored.
After updating, open up the program in SIMPL Windows and choose Project and
Re-Synch Program to get the new changes.
To update old modules, copy the signals from the existing modules to an instance
of the new module. Use the following steps to update OSD modules. The same
process can be used to update SATP and Keypad Presets modules.
1. Open the Crestron Project and OSD Demo.smw file with the new OSD module.
2. Use the Copy and Paste commands to add a new OSD module for every OSD
module in the project.
3. Right-click on the module to be updated and drag the module over the new
OSD module.
4. Select Copy All Signals/Parameters from the pop-up menu.
5. Click OK in the confirmation dialog box.
6. Delete the old module.
7. Repeat steps 3 through 6 for all the OSD modules to be updated.