Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches Contents infiNET™ Switches: CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Specifications .........................................................................................................
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches infiNET™ Switches: CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Introduction Features and Functions The CLW-SW1RF (-SW1RF) one-button switch and CLW-SW4RF (-SW4RF) four-button switch are stand-alone wall box switches that can also act as wireless infiNET™ devices that report to a Crestron® control processor via a Crestron infiNET wireless gateway. infiNET Switches Functional Summary • • • • Two-way infiNET switches ⇒ 2.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET Gateway and, if more devices are needed, more C2N-MNETGW gateways may be added to a Cresnet® network. Crestron infiNET switches operate on the 2.4 GHz “ISM band” (2400 MHz to 2483.6 MHz) at 10 mW. The output power of these devices allow RF signals to travel approximately 150 feet indoors and 250 feet outdoors (subject to site-specific conditions) without the use of repeaters or other infiNET devices.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches Specifications Following are specifications for the -SW1RF, -SW4RF, -SWS1RF, -SWS4RF, and -SLVS1RF. CLW-SW1/4RF, CLW-SWS1/4RF, & CLW-SLVS1RF Specifications SPECIFICATION DETAILS Power Requirements Line Power, 120 VAC, 60 Hz Operating Frequency 2400 MHz to 2483.6 MHz (802.15.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF CLW-SW1/4RF, CLW-SWS1/4RF, & CLW-SLVS1RF Specifications (continued) SPECIFICATION Dimensions and Weight (continued) 1. 2. 3. 4. 5. DETAILS -SLVS1RF: Height: 4.13 in (10.48 cm) Width: 1.75 in (4.45 cm) Depth: 1.88 in (4.77 cm) Weight: 3.6 oz (0.50 kg) The range is dependent on its placement and the building in which it is used.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches Physical View of CLW-SW1RF/-SWS1RF (Clockwise from Top; Top, Side, and Front) 1.75 in (4.45 cm) 2.38 in (6.03 cm) 1.88 in (4.77 cm) 3.81 in (9.68 cm) 3.28 in (8.32 cm) RUN SET 2.70 in (6.86 cm) 4.13 in (10.48 cm) OFF 1.50 in (3.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Physical View of CLW-SW4RF/-SWS4RF (Clockwise from Top; Top, Side, and Front) 1.75 in (4.45 cm) 2.38 in (6.03 cm) 1.88 in (4.77 cm) 3.81 in (9.68 cm) 3.28 in (8.32 cm) RUN SET 2.70 in (6.86 cm) 4.13 in (10.48 cm) OFF 1.50 in (3.81 cm) The -SLVS1RF is similar in appearance to the -SW1RF and -SWS1RF but does not have the three-position mode selection switch. The brightness of the LED on the -SLVS1RF is not programmable.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches Left to Right, CLW-SW1RF/-SWS1RF, CLW-SW4RF/-SWS4RF, and CLW-SLVS1RF; Shown in White Industry Compliance This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc. E239013 FCC ID: EROCWD1011 Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference and 2.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Acquire the Switch on the infiNET Network Before an infiNET device can be used on an infiNET network, it must first be acquired to a C2N-MNETGW gateway that is connected to a Cresnet network. NOTE: The -SW1RF, -SW4RF, -SWS1RF, and -SWS4RF can also work as standalone wall box switches without being acquired by a C2N-MNETGW. NOTE: A switch can be acquired to only one gateway.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF 3. infiNET™ Switches Take the C2N-MNETGW out of the Acquire mode once all devices have been acquired. Refer to the latest revision of the C2N-MNETGW Operations Guide (Doc. 6317), which is available from the Crestron website. To communicate with the control system program, an MNET ID value between 03 and 20 must be assigned to the switch. For information on assigning MNET ID values, refer to “Identity Code” on page 13.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Operation NOTE: The device may be warm to the touch during operation. This is normal. Mode Selection Switch These switches use a three-position mode selection switch to set the mode of operation. • OFF When the mode selection switch is in the “OFF” position, the pushbutton(s) will not have any function and the load is disconnected from the power source.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches • SET When the mode selection switch is in the “SET” position, it is operating in the SET mode. The LED will blink to indicate that the switch is in the SET mode. Refer to the following table for a list of available functions when the switch is operating in this mode. NOTE: The SET mode is only intended for adjusting the delay time. Under normal operation, the mode selection switch should be in the “RUN” position.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Switch Operation & LED Behavior LED BEHAVIOR LOW HIGH Four brief OFF blinks every eight seconds. Four brief HIGH blinks every eight seconds. Two brief OFF blinks every eight seconds. Blink OFF for ½ second, LOW for ½ second. Blink OFF for one second, HIGH for one second. Blink OFF for ¼ second, HIGH for ¼ second. 1. 2. DEVICE STATE In RUN mode, operating normally Device is in the bootloader.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches Identity Code Just like every device on a Cresnet system requires a unique identity code (NET ID), every device and user interface on the infiNET network requires a unique identity code (MNET ID). These codes are two-digit hexadecimal numbers from 03 to 20. The MNET ID of each unit must match an ID code specified in the SIMPL Windows program. Refer to “Programming with SIMPL Windows” on page 23 for details of the SIMPL Windows procedure.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF The infiNET switch and dimmers have already been acquired as described in the acquiring procedure described on page 8. The devices have been assigned the default MNET ID 01 as shown in the Network Device Tree window below. Network Device Tree 1. With the Network Device Tree open, select Tools | SMW Program Tree, or click . SMW Program Tree-Click to Select Program 2.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches SMW Program Tree Devices with NET IDs or MNET IDs that have been identified by the SMW icon. Devices with NET IDs or MNET Program Tree are marked with a IDs that could not be identified are marked with a icon. NOTE: Descriptions such as “BR Dimmer”, “LR Dimmer”, and “kitchen switch” were created by editing each devices symbol name in the SIMPL Windows Programming Manager.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF 4. In the SMW Program Tree, right-click on the top level of the tree and select Link with Network Control. Link with Network Control A window will be displayed with instructions for linking the SMW Program Tree to the Network Device Tree. Link Instruction Window ). 5. Click OK. The cursor will change to a target selector ( 6.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches Setup Lighting Window The listed devices can be sorted in ascending or descending order by clicking on the column headers. The order can also be adjusted by selecting a device and clicking the or buttons. This can be used when setting up devices in the order they will be encountered.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF The LEDs on all of the CLW-DIM1RF dimmers on the list will flash. 9. Physically locate the dimmer in the bedroom with the flashing LED and touch the top or bottom of the large button. The status of the “BR dimmer” will change from “Not Verified” to “Setup Complete” and the next device on the list (CLW-DIM1RF, MNET ID 03, “LR dimmer”) will be highlighted. Touching a device may result in setting a duplicate MNET ID. A warning will be displayed.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches Setup Complete 11. Click Close to close the window once all devices have been identified. All of the identified devices in the Network Device tree will be indicated with icon as shown in the following diagram.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF 2. Open the Network Device Tree and connect to the control system to verify that the gateway is connected to the control system and that all infiNET devices are acquired on the gateway. infiNET devices with MNET ID 01 will be shown with a icon as shown in the following diagram. “Network Device Tree” with Newly Added infiNET Device 3. Expand the device tree until the MNET ID that is to be changed is visible.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF 4. infiNET™ Switches Select a new MNET ID and press Enter. Enter New MNET ID Repeat this procedure for each additional infiNET device requiring a MNET ID change. WARNING: Devices with an MNET ID of 01 or 02 cannot be used in a control system program. These devices will be indicated with a icon. Operations Guide - DOC.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Programming Software Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestron’s True Blue Support, log in at http://support.crestron.com. First-time users will need to establish a user account.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches Programming with D3 Pro Crestron’s D3 Pro lighting software provides all the tools necessary to create a complete Crestron lighting system for residential applications. The lighting system includes the control system logic program, touchpanel projects and keypad programming, documentation and real-time lighting adjustment capabilities.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF • The system tree of the control system displays the device in the appropriate slot with a default MNET ID as shown in the following illustration. C2Net Device, Slot 6, with infiNET Device SIMPL Windows adds the selected infiNET device with a default MNET ID.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF • Program Manager infiNET™ Switches The MNET ID specified in the SIMPL Windows program must match the MNET ID of each unit. Refer to “Identity Code” on page 13. Program Manager is the view where programmers “program” a Crestron control system by assigning signals to symbols. The symbol can be viewed by double clicking on the icon or dragging it into Detail View. Each signal in the symbol is described in the SIMPL Windows help file (F1).
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. Once communication has been established, files (for example, programs or firmware) can be transferred to the control system (and/or device).
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Firmware infiNET™ Switches Check the Crestron website to find the latest firmware. (New users may be required to register to obtain access to certain areas of the site, including the FTP site.) Upgrade the infiNET device’s firmware via Crestron Toolbox. • Establish communication with the infiNET device and display the “System Info” window. • Select Functions | Firmware… to upgrade the infiNET device’s firmware.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Problem Solving Troubleshooting The table after this paragraph provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. infiNET Switch Troubleshooting TROUBLE Switch does not function. Switch does not respond to control system commands. POSSIBLE CAUSE(S) CORRECTIVE ACTION Switch is not receiving line power.
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches infiNET Switch Troubleshooting (continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Switch presses are not reported to control system. If the LED flashes OFF for ¼ second two times, then returns to low, the MNET ID of device is not set to match the MNET ID of the SIMPL Windows program. Using Crestron Toolbox, poll the network.
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF To enter the bootloader, set the mode selection switch to “OFF”. Press and hold the up button (or Button 1 on the -SW4RF or -SWS4RF) while setting the mode selection switch to “RUN”. The LED will blink once after five seconds to indicate the start of Acquire mode (Acquire mode does not actually start until you release the button).
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.