Specifications
infiNET™ SWITCHES
b. Press and hold the top or bottom of the
button on the -SW1RF/-SWS1RF or
any button on the -SW4RF/-SWS4RF.
Problem Solving
Troubleshooting
c. While holding the button, slide the
mode selection switch to the “RUN”
position.
The table after this paragraph provides corrective action
for possible trouble situations. If further assistance is
required, please contact a Crestron customer service
representative.
d. Hold the button for approximately five
seconds until the LED flashes HIGH
once. Immediately release the button
after the LED blinks to start the
switch’s Acquire mode.
infiNET Switch Troubleshooting
TROUBLE POSSIBLE
CAUSE(S)
CORRECTIVE ACTION
Switch is not
receiving
line power.
Verify that the switch is
properly connected to
power line and that the
circuit breaker is closed.
Switch
does not
function.
Load is not
connected.
Verify that load is
operational and that the
mode selection switch is in
the RUN position.
NOTE: Holding the button for a significant
time after the first flash may enter other modes.
If this is not desired, return the mode selection
switch to the “OFF” position without releasing
the button and repeat step 2.
After approximately ten seconds, the LED will
start to blink slowly and the switch will attempt
to acquire with a C2N-MNETGW that is in the
Acquire mode. The device is acquired when the
LED stops blinking and lights at the LOW
setting. After being acquired, the device will exit
the Acquire mode.
The switch will be acquired on the
C2N-MNETGW with an MNET ID value of 01.
If the switch was previously acquired on another
infiNET network, the switch will be acquired on
the C2N-MNETGW with its previous MNET ID.
If the switch does not function after performing the above
corrective actions, restore the switch’s default settings by
moving the mode selection switch to the “RUN” position.
While holding the pushbutton (hold “UP” on the -SW1RF
and -SWS1RF, or hold Button 1 on the -SW4RF or
-SWS4RF), move the mode selection switch to the “SET”
position and back to the “RUN” position. Release the
pushbutton. The LED will flash once to confirm that the
default values have been restored.
Further Inquiries
If you cannot locate specific information or have
questions after reviewing this guide, please take
advantage of Crestron's award winning customer service
team by calling the Crestron corporate headquarters at
1-888-CRESTRON [1-888-273-7876].
3. Take the C2N-MNETGW out of the Acquire
mode once all devices have been acquired. Refer
to the latest revision of the C2N-MNETGW
Operations Guide (Doc. 6317), which is
available from the Crestron website.
You can also log onto the online help section of the
Crestron website (
www.crestron.com/onlinehelp) to ask
questions about Crestron products. First-time users will
need to establish a user account to fully benefit from all
available features.
For more information, refer to the latest version of the
infiNET Switches Operations Guide (Doc. 6397) which is
available from the Crestron website.
Future Updates
As Crestron improves functions, adds new features, and
extends the capabilities of the device, additional
information may be made available as manual updates.
These updates are solely electronic and serve as
intermediary supplements prior to the release of a
complete technical documentation revision.
Check the Crestron website periodically for manual
update availability and its relevance. Updates are
identified as an “Addendum” in the Download column.
Installation Guide - DOC. 6293C infiNET™ Wall Box Switch: CLW-SW1/4RF, SWS1/4RF, & SLVS1RF • 7