infiNET™ SWITCHES
Derating Information for Fluorescent/HID Applications
Part
Number
No Side
Removed
One Side
Removed
Two Sides
Removed
-SW1RF/
-SW4RF
8A 5.5A 4.5A
-SWS1RF/
-SWS4RF
8A 5.5A 4.5A
-SLVS1RF No Derating Necessary
Derating Information for Ceiling Fans
Part
Number
No Side
Removed
One Side
Removed
Two Sides
Removed
-SW1RF/
-SW4RF
3A 3A 3A
-SWS1RF/
-SWS4RF
3A 3A 3A
-SLVS1RF No Derating Necessary
2. To remove a side section, bend the side section
back and forth with a pair of pliers until the
section breaks off from the mounting plate. Use a
file or sandpaper to remove any excess metal.
Installation
WARNING: Turn off power at the circuit breaker.
Installing with power on can result in serious personal
injury and damage to the device.
NOTE: The -SW1RF, -SW4RF, -SWS1RF, and
-SWS4RF require a neutral wire for operation. If no
neutral is present, the device will not work. If no neutral
is present, contact a licensed electrician for installation.
NOTE: The -SWS1RF and -SWS4RF must be installed
in the same wallbox that contains the connections to the
load.
NOTE: New installations should be checked for short
circuits prior to installing the -SW1RF, -SW4RF,
-SWS1RF, -SWS4RF, or -SLVS1RF. With power off,
close the circuit and restore power. If the load does not
work or a breaker trips, check and correct the wiring or
fixture (if necessary). Install the -SW1RF, -SW4RF,
-SWS1RF, -SWS4RF, or -SLVS1RF only when the short
is no longer present. The warranty is void if the
-SW1RF, -SW4RF, -SWS1RF, -SWS4RF, or
-SLVS1RF is installed and operated with a shorted
load.
When installing a -SWXRF or a -SWSXRF without a
slave, follow the instructions in “Wiring a -SW(S)XRF
(No Slaves)” below. If wiring a -SWSXRF with a
-SLVS1RF, refer to “Wiring a -SWSXRF with One or
More -SLVS1RFs” in the next column.
Wiring a -SW(S)XRF (No Slaves)
The following describes the installation of a stand-alone
-SW1RF, -SW4RF, -SWS1RF or -SWS4RF.
1. Turn power off at the circuit breaker.
2. Wire the switch as shown in Figure 1 on
page 9.
NOTE: The RED (Load) and BLACK (Hot)
wires are #14 AWG. The BLUE (Slave) and
WHITE (Neutral) wires are #18 AWG. The
GREEN (Ground) wire is #16 AWG.
NOTE: Since the -SWS1RF or -SWS4RF is
installed without a -SLVS1RF, the BLUE lead
(Slave) should be capped.
Other Wiring
For another scenario that may be encountered
during installation, refer to Figure 2 on page 9.
3. Push all power wires back into the wallbox and
fasten the device to the wallbox with the
provided screws.
4. Attach decorative faceplate.
5. Restore power at the circuit breaker.
Wiring a -SWSXRF with One or More
-SLVS1RFs
NOTE: The -SWS1RF and -SWS4RF must be installed
in the same wallbox that contains the connections to the
load.
The following describes installation of a -SWSXRF
master with a -SLVS1RF slave.
1. Turn power off at the circuit breaker.
2. Wire the switches as shown in Figure 3 on
page 9.
NOTE: Do not connect the BLUE (Slave) wire
to the Black (Hot) or RED (Load) wires.
NOTE: The RED (Load) and BLACK (Hot)
wires are #14 AWG. The BLUE (Slave) and
WHITE (Neutral) wires are #18 AWG. The
GREEN (Ground) wire is #16 AWG.
NOTE: If a -SWS1RF or -SWS4RF is installed
without a -SLVS1RF, the BLUE lead (Slave)
should be capped.
NOTE: The WHITE (Neutral) connection on
the -SLVS1RF is optional and is only required
Installation Guide - DOC. 6293C infiNET™ Wall Box Switch: CLW-SW1/4RF, SWS1/4RF, & SLVS1RF 5