Specifications

Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System
Operations Guide DOC. 6347G iLux Integrated Lighting System: CLS/CLSI-C6 & CLS/CLSI-C6M 79
FUNCTION
NAME
CLOSE MOMENTARY/CLOSE FULL
(ALL, GROUP 16)
Behavior Same as “Open Momentary/Open Full Shade Group 1–6”
except Close.
LED On while button is pressed
Applies To Remote Button
Rocker Behavior N/A
Notes Same as “Open Momentary/Open Full Shade Group 16.”
FUNCTION
NAME
OPEN/STOP/CLOSE/STOP (ALL, GROUP 16)
Behavior Function alternates between the “Full Open,” “Stop,” and
“Full Close” commands for the specified shade group(s)
each time the button is pressed.
LED On while button is pressed
Applies To Standard Rocker, Shifted Rocker, Remote Button, up/down
(All only)
Rocker Behavior
Pressing center of the button acts the same as non-rocker
open/stop/close/stop. Pressing only one side of the button
while stopped always send it in specified direction rather
than in opposite of last direction. Pressing any part of the
button while the shade is moving stops it. For up/down
rocker button behavior, see below:
bottom button = left button => close.
top button = right button => open.
Notes Shade commands with “All” parameter only affects all the
shade groups connected to the given CLS-C6 module. They
do not pass from one CLS-C6 module to the other (either
when directly connected or when linked through a Cresnet
system). To accomplish this function for all shades in a
multi-unit system, use SIMPL programming.
FUNCTION
NAME
EXTERNAL FUNCTION (132)
Behavior Activates the corresponding “press” digital signal (press1
press32 on the External Functions slot) on the Cresnet
system connected to the CONTROL SYSTEM port. Signal
remains high for as long as the button is pressed.
LED On when the corresponding “fb” digital signal (fb1fb32 on
the External Functions slot) from the control system is high.
Applies To Shifted Rocker, Remote Button
Rocker Behavior Left, right, and both all do the same thing
Notes Note that these should only be assigned to a CLS-C6 unit
that is directly connected to a Cresnet control system, or to
keypads connected to that unit’s local devices network.