FUNCTION
NAME
OPEN SHADES FULL (ALL, GROUP 16)
Behavior Sends the specified shades to Full Open position.
LED On while button is pressed
Applies To Remote Button
Rocker Behavior N/A
Notes Shade commands with “All” parameter only affect all the
shade groups connected to the given CLS-C6 module. They
do not pass from one CLS-C6 module to another (either
when directly connected or when linked through a Cresnet
system). If all shades are to open in a multi-unit system,
define a scene to do that.
FUNCTION
NAME
CLOSE SHADES FULL (ALL, GROUP 16)
Behavior Sends the specified shades to Full Closed position.
LED On while button is pressed
Applies To Remote Button
Rocker Behavior N/A
Notes Shade commands with “All” parameter only affect all the
shade groups connected to the given CLS-C6 module. They
do not pass from one CLS-C6 module to the other (either
when directly connected or when linked through Cresnet
system). If all shades are to close in a multi-unit system,
define a scene to do that.
FUNCTION
NAME
STOP SHADES (ALL, GROUP 16)
Behavior Stops the specified shades at current position.
LED On while button is pressed
Applies To Remote Button
Rocker Behavior N/A
Notes Shade commands with “All” parameter only affect all the
shade groups connected to the given CLS-C6 module. They
do not pass from one CLS-C6 module to the other (either
when directly connected or when linked through Cresnet
system). To accomplish this function for all shades in a
multi-unit system, use SIMPL programming.