Specifications
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M
18 • iLux Integrated Lighting System: CLS-C6/C6M & CLSI-C6/C6M Operations Guide – DOC. 6347G
that button. When the button is released, the LED for that button should
flash once to indicate that programming took place.
2. Next, use the up/down button to scroll to the next function and value to
be assigned, and assign the desired buttons. Repeat this procedure for
each function and value to be assigned.
3. After assigning all button functions, press Save to save the button
function information. If Cancel is pressed or the “Setup Button
Functions” option is exited by some other mechanism (e.g., timeout),
the state returns to what it was before Setup mode was entered.
NOTE: The ON and OFF buttons on the CLS-C6 cannot be
programmed. The operation of the up/down button is programmed
using the “ud” setup function.
• If an illegal button is programmed (e.g., the ON button or the remote
keypad is programmed as master raise/lower-up/down), LED flashes three
times to indicate that setting did not take place and the 2-digit display shows
“Er.”
NOTE: Other button functions, including shifted functions, can be defined
using the iLux Designer configuration program.
Setup Up/Down Button Function (ud)
To define operation of the up/down button, enter Setup mode and scroll to the “ud”
option (using the and buttons).
• Use the up/down button to select the desired mode. The display flips
between “ud.” and “#” where “#” is the mode, as defined in the following
table.
FUNCTION MODE
Lights (Last Scene) Master Up/Down L
Shades Master Up/Down S
• The first function to be displayed is the current function. Since there are
other functions that can be programmed via the iLux Designer, if the current
function is not one of these, the display should show “ud. – –”. Pressing the
up/down button then goes to mode L.
• Press Save to save the new setting or Cancel to retain the original setting.
Setup Occupancy Sensing (oc)
To define operation of the occupancy sensing feature, enter Setup mode and scroll to
the “oc” option (using the and buttons).
• Use the up/down button to select the desired mode. The display alternates
between “oc.” and the mode number, as defined in the following table.
MODE CODE
Do nothing on either exit or entry 0
Recall specified scene on exit, do nothing on entry 1
Recall specified scene on entry, do nothing on exit 2
Recall specified scenes on entry and exit 3