Specifications
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System
Operations Guide – DOC. 6347G iLux Integrated Lighting System: CLS/CLSI-C6 & CLS/CLSI-C6M • 15
while the display is at a level below the LE limit or above the HE limit, the
displayed value is saved but the light level is limited to the programmed
limits.
• If a lighting load is defined as an unused load type, the bar graph for that
lighting load has all LEDs off. If the lighting load is adjusted, the 2-digit
display shows “Er.”
• To mark a lighting load as not affected (i.e., the lighting load’s current state
is not changed by recalling the scene), press and hold the center of the
corresponding button for 3 seconds. Adjustments made to such lighting
loads cancel the not affected condition and start adjusting from the current
light level.
• While adjustments are being made to the lights or shades, the 2-digit display
shows the level, just like in Manual mode. The level for loads that are not
affected is shown as “– –”. In Manual mode, the display goes blank after 3
seconds; in scene programming, the display returns to “Sc. ##”.
• For shades, when the left or right side of the button is pressed, the 2-digit
display immediately shows full open or full closed as soon as the shade
starts moving. The preset is set to this full open or full closed position even
if the shade is stopped before reaching the full open or full close position.
• The iLux Designer or SIMPL Windows programs can lock a scene to
prevent it from being changed using the front panel controls. If the selected
scene is locked in the configuration when an adjustment is made, “Er” is
displayed for 3 seconds and the scene remains in its existing state.
• To adjust the fade time, while “Sc. ##” is displayed, press the and
buttons to adjust the time. The first time a button is pressed current fade
time is shown but not changed. Subsequent presses change the displayed
value. Adjustment to fade time can be made when either Lights mode or
Shades mode is active.
When increasing the time, the value goes from 0 seconds to 59 seconds, and
then 1 minute to 99 minutes. When decreasing the time, the value goes from
99 minutes to 1 minute, and then 59 seconds to 0 seconds.
• To save or cancel levels, press the Save button to save the new values and
return to Standard mode. Press the Cancel button to return to Standard
mode without saving; previously saved scene parameters are remembered.
Setup Lighting Load Types (Ld)
To set the load types for each lighting load, first enter Setup mode and scroll to the
“Ld” option. The bar graphs immediately indicate the currently selected load type for
each lighting load. Use the function buttons to change the load type. Each load type
is indicated by a pattern of bar graph segments and a number on the 2-digit display,
as shown in the following table. Press the right and left side of the buttons to cycle
through the available load types.