Specifications

iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M
8 iLux Integrated Lighting System: CLS-C6/C6M & CLSI-C6/C6M Operations Guide DOC. 6347G
CLS-C6 Rear Panel
Connectors, Controls, and Indicators
# CONNECTORS
,
CONTROLS, AND
INDICATORS
DESCRIPTION
1 Bar Graphs
In Standard mode and Lights mode, the bar
graphs, each a series of seven LEDs, indicate
the current light intensity for the six lighting
loads. When under photocell control, the top
bar graph LED for a controlled load blinks. In
Shades mode, they indicate the shade
position for each of the shade groups. The bar
graphs have other functions in Setup mode.
2 Label Strip Customizable label for the six scenes.
3 Function Buttons and
LEDs
In Standard mode, these buttons are typically
used to select/recall scenes. In Lights mode,
they are used to make temporary adjustments
to the six lighting loads. In Shades mode they
are used to make temporary adjustments to
the shade groups. They can also be
programmed to perform other functions.
4 IR Detector The IR detector responds to commands from
the optional Crestron remote control. The
remote control can be used to recall Scenes 1
through 4 and the On and Off scenes, as well
as perform master raise and lower of the
lighting loads.
5 Motion Detector
(CLS/CLSI-C6M only)
The built-in motion detector can be used to
activate a particular scene when there is
activity in the room and/or to activate a
particular scene (typically Off) when there is
no activity for a specified period. A limited
number of actions are available when
programmed locally; more are available using
the iLux Designer software program.
6 Mini Phone Jack Use this 3.5 mm TRS mini-phone jack,
located on the front panel, as an RS-232
programming port to communicate with the
iLux Designer and Crestron Toolbox
to
configure the unit and to upgrade the unit’s
firmware.