Specifications

Crestron CEN-RGBHVHB High-Bandwidth RGB Matrix Switcher
Operations Guide DOC. 7157C High-Bandwidth RGB Matrix Switcher: CEN-RGBHVHB 31
NOTE: Input termination impedance settings are applied to the H and V sync
connections for the selected input.
Press ENTER to select between the two values; press MENU to accept the desired
value and return to the “Video Setup” category screen. Use the quick-adjust knob to
select another category. The next category is Blanking Setup.
Blanking Setup
“Blanking Setup” Screen
Setup Menu
Blanking Setup
To set up blanking, press the ENTER button
Blanking Setup Screen 2
To adjust blanking
select an output
Press a front panel OUT button to select an output to adjust.
For example, to set blanking for output number 1, press the OUT button below 1 on
the front panel. The LED above OUT 1 lights and the current blanking setting for
output 1 is displayed.
“Out 1 Blanking” Screen
** Out 1 Blanking **
0.0 sec
Use the quick-adjust knob to change the blanking time. In this example, the blanking
for output 1 is changed from 0 to 0.5 seconds. The display shows the change in
blanking time along with a bar graph.
“Blanking” Screen
Blanking 0.5 sec
Press ENTER to save the new setting. The display returns to the “Blanking Setup”
screen. Press ENTER to select another output.
Use the quick-adjust knob to select another category. The next category is Network