Installation guide

Crestron CEN-NVS200 Network Video Streamer
Operations & Installation Guide DOC. 7111E Network Video Streamer: CEN-NVS200
13
Setup
Network Wiring
The CEN-NVS200 requires the use of a high-speed Ethernet connection for control
system communications. It is powered by its PoE connection.
For information on connecting Ethernet devices in a Crestron system, refer to the
Crestron e-Control
Reference Guide (Doc. 6052) at www.crestron.com/manuals.
Supplied Hardware
The hardware supplied with the CEN-NVS200 is listed in the following table.
Supplied Hardware for the CEN-NVS200
DESCRIPTION PART NUMBER QUANTITY
Mounting Bracket 2022739 1
M3 x 5 mm Phillips Screws 2022785 4
BNC to RCA Adapter 2022817 1
Installation
Ventilation
The CEN-NVS200 should be used in a well-ventilated area.
To prevent overheating, do not operate this product in an area that exceeds the
environmental temperature range listed in the table of specifications. Consider using
forced air ventilation and/or incrementing the spacing between units to reduce
overheating. Consideration must be given if installed in a closed or multi-unit rack
assembly since the operating ambient temperature of the environment may be greater
than the room ambient temperature. Contact with thermal insulating materials should
be avoided on all sides of the unit.
Mounting
The CEN-NVS200 can be mounted on a surface, a rack rail or stacked with other
equipment. The included mounting bracket must be attached to the CEN-NVS200
before the device is mounted.
NOTE: No more than two CEN-NVS200 units should be stacked.
Attaching the Mounting Bracket
Attach the mounting bracket (2022739) to the bottom of the CEN-NVS200 using the
four included M3 x 5 mm Phillips screws (2022785), as shown in the following
illustration.